MRI-Based Attenuation Correction for PET/MRI Using Multiphase Level-Set Method.

نویسندگان

  • Hyun Joon An
  • Seongho Seo
  • Hyejin Kang
  • Hongyoon Choi
  • Gi Jeong Cheon
  • Han-Joon Kim
  • Dong Soo Lee
  • In Chan Song
  • Yu Kyeong Kim
  • Jae Sung Lee
چکیده

UNLABELLED Inaccuracy in MR image-based attenuation correction (MR-AC) leads to errors in quantification and the misinterpretation of lesions in brain PET/MRI studies. To resolve this problem, we proposed an improved ultrashort echo time MR-AC method that was based on a multiphase level-set algorithm with main magnetic field (B0) inhomogeneity correction. We also assessed the feasibility of this level-set-based MR-AC method (MR-AC(level)), compared with CT-AC and MR-AC provided by the manufacturer of the PET/MRI scanner (MR-AC(mMR)). METHODS Ten healthy volunteers and 20 Parkinson disease patients underwent(18)F-FDG and(18)F-fluorinated-N-3-fluoropropyl-2-β-carboxymethoxy-3-β-(4-iodophenyl)nortropane ((18)F-FP-CIT) PET scans, respectively, using both PET/MRI and PET/CT scanners. The level-set-based segmentation algorithm automatically delimited air, bone, and soft tissue from the ultrashort echo time MR images. For the comparison, MR-AC maps were coregistered to reference CT. PET sinogram data obtained from PET/CT studies were then reconstructed using the CT-AC, MR-AC(mMR), and MR-AC(level) maps. The accuracies of SUV, SUVr (SUV and its ratio to the cerebellum), and specific-to-nonspecific binding ratios obtained using MR-AC(level) and MR-AC(mMR) were compared with CT-AC using region-of-interest- and voxel-based analyses. RESULTS There was remarkable improvement in the segmentation of air cavities and bones and the quantitative accuracy of PET measurement using the level set. Although the striatal and cerebellar activities in (18)F-FP-CIT PET and frontal activity in (18)F-FDG PET were significantly underestimated by the MR-AC(mMR), the MR-AC(level) provided PET images almost equivalent to the CT-AC images. PET quantification error was reduced by a factor of 3 using MR-AC(level) (SUV error < 10% in MR-AC(level) and < 30% in MR-AC(mMR) [version VB18P], and < 5% in MR-AC(level) and < 15% in MR-AC(mMR) [VB20P]). CONCLUSION The results of this study indicate that our new multiphase level-set-based MR-AC method improves the quantitative accuracy of brain PET in PET/MRI studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Automated body-lung-air material map segmentation from pre-clinical MRI images for PET attenuation correction in Tera-Tomo 3D PET reconstruction engine of nanoScan PET/MRI system

Department of Software Engineering, Mediso Ltd., Budapest, Hungary The aim of current work was to automatically derive a body-lung-air three-valued material map from MRI images for pre-clinical PET attenuation correction. Our goal was also to measure the effect of attenuation on corresponding pre-clinical PET images. 12 mouse and 9 rat PET/MRI images were acquired by nanoScan PET/MRI (Mediso). ...

متن کامل

MRI-based attenuation correction for PET/MRI using ultrashort echo time sequences.

UNLABELLED One of the challenges in PET/MRI is the derivation of an attenuation map to correct the PET image for attenuation. Different methods have been suggested for deriving the attenuation map from an MR image. Because the low signal intensity of cortical bone on images acquired with conventional MRI sequences makes it difficult to detect this tissue type, these methods rely on some sort of...

متن کامل

Feasibility of MRI attenuation correction in cardiac FDG-PET

Background Simultaneous acquisition PET-MRI is a new technology that has the potential to significantly impact diagnostic patient care. Cardiac imaging using PET-MRI offers high signal resolution MRI images superimposed on PET metabolic functional assessment. Specifically, 18Ffluorodeoxyglucose (FDG) PET-MR has the potential to provide both anatomic scar tissue evaluation and information regard...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 57 4  شماره 

صفحات  -

تاریخ انتشار 2016