Validity of the Water Hammer Formula for Determining Regional Aortic Pulse Wave Velocity: Comparison of One-Point and Two-Point (Foot-to-Foot) Measurements Using a Multisensor Catheter in Human.

نویسنده

  • Shizuo Hanya
چکیده

BACKGROUND Lack of high-fidelity simultaneous measurements of pressure and flow velocity in the aorta has impeded the direct validation of the water-hammer formula for estimating regional aortic pulse wave velocity (AO-PWV1) and has restricted the study of the change of beat-to-beat AO-PWV1 under varying physiological conditions in man. METHODS Aortic pulse wave velocity was derived using two methods in 15 normotensive subjects: 1) the conventional two-point (foot-to-foot) method (AO-PWV2) and 2) a one-point method (AO-PWV1) in which the pressure velocity-loop (PV-loop) was analyzed based on the water hammer formula using simultaneous measurements of flow velocity (Vm) and pressure (Pm) at the same site in the proximal aorta using a multisensor catheter. AO-PWV1 was calculated from the slope of the linear regression line between Pm and Vm where wave reflection (Pb) was at a minimum in early systole in the PV-loop using the water hammer formula, PWV1 = (Pm/Vm)/ρ, where ρ is the blood density. AO-PWV2 was calculated using the conventional two-point measurement method as the distance/traveling time of the wave between 2 sites for measuring P in the proximal aorta. Beat-to-beat alterations of AO-PWV1 in relationship to aortic pressure and linearity of the initial part of the PV-loop during a Valsalva maneuver were also assessed in one subject. RESULTS The initial part of the loop became steeper in association with the beat-to-beat increase in diastolic pressure in phase 4 during the Valsalva maneuver. The linearity of the initial part of the PV-loop was maintained consistently during the maneuver. Flow velocity vs. pressure in the proximal aorta was highly linear during early systole, with Pearson's coefficients ranging from 0.9954 to 0.9998. The average values of AO-PWV1 and AO-PWV2 were 6.3 ± 1.2 and 6.7 ± 1.3 m/s, respectively. The regression line of AO-PWV1 on AO-PWV2 was y = 0.95x + 0.68 (r = 0.93, p <0.001). CONCLUSION This study concluded that the water-hammer formula (one-point method) provides a reliable and conventional estimate of beat-to-beat aortic regional pulse wave velocity consistently regardless of the changes in physiological states in human clinically. (English Translation of J Jpn Coll Angiol 2011; 51: 215-221).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The new empirical formula to estimate the uniaxial compressive strength of limestone; south west of Tehran-Iran, as a case study

In many rock engineering projects, accurate identification of rock strength properties is very important. Uniaxial compressive strength is one of the most important features to describe the resistive behavior of rocks which is used as an important parameter in the design of structures especially underground openings. Determination of this parameter using direct methods, including uniaxial compr...

متن کامل

Comparison of techniques for measuring pulse-wave velocity in the rat.

We evaluated methods for measuring average and regional pulse-wave velocity along the full length of the aorta in 18-mo-old ether-anesthetized male spontaneously hypertensive rats. Catheter-tip manometers were placed in the ascending and descending thoracic aorta via the right carotid and left femoral arteries, respectively. As the distal catheter was withdrawn at 1-cm intervals, the relationsh...

متن کامل

A database of virtual healthy subjects to assess the accuracy of foot-to-foot pulse wave velocities for estimation of aortic sti↵ness

1 While central (carotid-femoral) foot-to-foot pulse wave velocity (PWV) is considered to be 2 the gold standard for the estimation of aortic arterial sti↵ness, peripheral foot-to-foot PWV 3 (brachial-ankle, femoral-ankle, carotid-radial) are being studied as substitutes of this central 4 measurement. We present a novel methodology to assess theoretically these computed indices 5 and the hemody...

متن کامل

The Comparison of the Difference in Foot Pressure, Ground Reaction Force, and Balance Ability According to the Foot Arch Height in Young Adults

Background. Human feet have important roles in supporting, moving and balancing the body. The feet must not only support the weight of the body but must also have the elasticity to absorb the burden associated with supporting excessive body weight. Objectives. The purpose of this study was to compare the difference of foot pressure, ground reaction force, and balance ability according to chang...

متن کامل

A database of virtual healthy subjects to assess the accuracy of foot-to-foot pulse wave velocities for estimation of aortic stiffness

While central (carotid-femoral) foot-to-foot pulse wave velocity (PWV) is considered to be the gold standard for the estimation of aortic arterial stiffness, peripheral foot-to-foot PWV (brachial-ankle, femoral-ankle, and carotid-radial) are being studied as substitutes of this central measurement. We present a novel methodology to assess theoretically these computed indexes and the hemodynamic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of vascular diseases

دوره 6 2  شماره 

صفحات  -

تاریخ انتشار 2013