An implantable semiconductor beta-radiation detector.
نویسندگان
چکیده
An implantable beta-radiation detector suitable for the measurement of reginal blood flow in the experimental animal by the indicator clearance principle is described. A lithium-drifted silicon diode encapsulated in a stainless steel case is sutured over the site of interest. A suitable beta-emitting isotope, such as 85Kr in saline solution, is injected into the arterial supply and its calibrated against a mechanical system and showed excellent agreement up to 600 ml/100 g per min. At very high rates beyond the physiological range, flow was underestimated by a maximum of 10%. In vivo comparisons of myocardial blood flow assessed by the beta detector did not agree well with estimates of flow from a precordial counter or by the microsphere technique. Possible reasons are spatial heterogeneity of regional myocardial blood flow, the greatly different masses of tissue involved, or our inability to achieve sufficient numbers of spheres for accuracy in a 50-mg mass of tissue. The unit was still functional after 50 days in a chronic animal.
منابع مشابه
Conceptual Design and Simulation of Alpha-Beta Detector for Surface Contamination Measurements
The radioactive contamination measurement is essential in nuclear facilities. Monitoring of low level alpha and beta contamination is possible using light detectors high efficiency. Due to the fact that many detectors canchr('39')t simultaneously discriminate alpha, beta and gamma rays; among existing methods, phoswich detectors would be appropriate option to measure different radioactive conta...
متن کاملOptimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system
Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...
متن کاملIdentification of photons in double beta-decay experiments using segmented germanium detectors - studies with a GERDA Phase II prototype detector
The sensitivity of experiments searching for neutrinoless double beta-decay of germanium was so far limited by the background induced by external γ-radiation. Segmented germanium detectors can be used to identify photons and thus reduce this background component. The GERmanium Detector Array, GERDA, will use highly segmented germanium detectors in its second phase. The identification of photoni...
متن کاملSemiconductor high-energy radiation scintillation detector
We propose a new scintillation-type detector in which high-energy radiation generates electron–hole pairs in a direct-gap semiconductor material that subsequently recombine producing infrared light to be registered by a photo-detector. The key issue is how to make the semiconductor essentially transparent to its own infrared light, so that photons generated deep inside the semiconductor could r...
متن کاملشبیه سازی یک آشکارساز تناسبی میکرو نواری برای آشکارسازی گاز رادن و دختران با کد مونت کارلو (MCNPX)
Many detection methods have been applied to detect radon gas. Due to the low noise and high resolution of gas detectors compared to semiconductor detectors or scintillation detectors, using them to detect alpha radiation is very considerable. Microstrip proportional detector is also included in this group and it has not been used for the detection of radon. In this article, response of the micr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The American journal of physiology
دوره 232 1 شماره
صفحات -
تاریخ انتشار 1977