Fully Truncated Cone-Beam Reconstruction on Pi Lines Using Prior CT
نویسندگان
چکیده
C-arms are well suited for obtaining cone-beam projections intra-operatively. Due to the compact size of the detector used, the data are usually truncated within the field of view. As a result, direct application of a standard cone-beam reconstruction algorithm gives rise to undesirable artifacts and incorrect values in the reconstructed image volume. When prior information such as a pre-operative CT scan is available, fully truncated cone-beam projections can be used to recover the change within a small region of interest without such artifacts. A method for integrating prior CT is developed using the concept of pi-lines and tested on real flat-panel and simulated cone-beam data.
منابع مشابه
Fan-beam and cone-beam image reconstruction via filtering the backprojection image of differentiated projection data.
In this paper, a new image reconstruction scheme is presented based on Tuy's cone-beam inversion scheme and its fan-beam counterpart. It is demonstrated that Tuy's inversion scheme may be used to derive a new framework for fanbeam and cone-beam image reconstruction. In this new framework, images are reconstructed via filtering the backprojection image of differentiated projection data. The new ...
متن کاملStudies on implementation of the Katsevich algorithm for spiral cone-beam CT
Recently, Katsevich proposed the first exact helical cone-beam reconstruction algorithm that takes longitudinally truncated data collected from part of a scanning turn. A key theoretical basis is that any point inside the scanning helix belongs to one and only one PI-line. Unfortunately, he only provided a general formulation and did not describe the implementation details. To make this complic...
متن کاملExact Interior Reconstruction with Cone-Beam CT
Using the backprojection filtration (BPF) and filtered backprojection (FBP) approaches, respectively, we prove that with cone-beam CT the interior problem can be exactly solved by analytic continuation. The prior knowledge we assume is that a volume of interest (VOI) in an object to be reconstructed is known in a subregion of the VOI. Our derivations are based on the so-called generalized PI-se...
متن کاملMinimum detection windows, PI-line existence and uniqueness for helical cone-beam scanning of variable pitch.
The goal of this paper is to study Cone-beam CT scanning along a helix of variable pitch. First the rationale and applications in medical imaging of variable pitch CT reconstruction are explained. Then formulas for the minimum detection window are derived. The main part of the paper proves a necessary and sufficient condition for the existence and uniqueness of PI-lines inside this variable pit...
متن کاملTime-resolved cardiac interventional cone-beam CT reconstruction from fully truncated projections using the prior image constrained compressed sensing (PICCS) algorithm.
C-arm cone-beam CT could replace preoperative multi-detector CT scans in the cardiac interventional setting. However, cardiac gating results in view angle undersampling and the small size of the detector results in projection data truncation. These problems are incompatible with conventional tomographic reconstruction algorithms. In this paper, the prior image constrained compressed sensing (PI...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention
دوره 8 Pt 1 شماره
صفحات -
تاریخ انتشار 2005