Single-Phase Shunt Active Power Filter Using Indirect Control Method

نویسنده

  • Rejil Chandran
چکیده

A single-phase shunt active power filter is used mainly for the elimination of harmonics in single-phase AC networks. In this paper a single-phase shunt active power filter based on, an indirect control technique is designed and simulated. This control technique is achieved by phase shifting the input signal(voltage/current) by π/2.The overall action of the shunt active power filter to eliminate the harmonics created by a non-linear load on the source side is discussed in this paper and the output of the shunt active power filter is verified using MATLAB/Simulink software package.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Indirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays

The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...

متن کامل

A Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach

This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...

متن کامل

A Hybrid Control Method for Stable Operation of Active Power Filters in Three-Phase Four-Wire Networks

The main goal of this study is the use of Lyapunov’s stability theory to a three-phase four-wire shunt active power filter (SAPF), since this method has been applied effectively to other areas of converter. The dynamic model of the SAPF is first established, after that, a combination of fuzzy tracking control and Lyapunov function is suggested in order to impose a desired transient waveform on ...

متن کامل

Power quality enhancement using cascaded multilevel inverter based shunt hybrid active power filter

This paper investigates mitigation of current harmonics using different configuration of cascaded multilevel inverter based shunt hybrid active power filter (SHAPF) and to improve power quality of the system. The main objective of this paper is to develop and analyze the compensation characteristics of cascaded multilevel inverter based shunt hybrid active power filter by employing indirect cur...

متن کامل