Microscopy analysis of breast implant rupture caused by surgical instrument damage.
نویسندگان
چکیده
BACKGROUND The mechanism of breast implant rupture has continued to be an important topic throughout the plastic surgery community and regulatory agencies, such as the US Food and Drug Administration. Retrieved ruptured implants returned to Allergan (Santa Barbara, CA; formerly Inamed Corporation) for analysis exhibit various modes of failure, which can include a small pinhole (approximately 1 to 2 mm in size) in the shell, a ruptured shell, or a severely fragmented shell. OBJECTIVE The failure mechanisms and associated morphologic features for the modes of implant failure can be quite different. The objective of this study is to analyze and describe the rupture characteristics of silicone gel-filled implants that failed because of surgical instrument damage. METHODS There are several types of diagnostic techniques available to analyze ruptured implants. Visual inspection, physical examination, and photographic analysis provided an overall description of the implant shape and gross features of the shell failure region. These techniques allowed categorization and documentation of the mode of failure and were quite useful as a supplemental tool in the diagnosis of implant failure mechanisms. Microscopy techniques provided details of the ruptured shell region and could be used to determine the cause of breast implant failure. This study involved the use of optical microscopy and scanning electron microscopy in the analysis of ruptured breast implants. RESULTS Details of the geometry of ruptured shell regions are described. Illustrations are also presented in which 35-mm photography is used to assist in substantiating the cause of failure. Many of the ruptured regions exhibit striations across the thickness of the shell. Micrographs are presented that clearly show that the striations are due to lines in the cutting surface of the surgical instrument that were formed during the manufacturing process. CONCLUSIONS This article demonstrates that, with the proper background and experience in analyzing ruptured breast implant shells, the features at the failure site can be correctly interpreted and the corresponding failure mechanisms can be diagnosed. Breast implants are subject to surgical instrument damage during implantation, and this damage can develop into a shell rupture, with the failure mode identifiable via microscopy analysis.
منابع مشابه
Thoracic Outlet Syndrome Following Breast Implant Rupture
We present a patient with bilateral breast implant rupture who developed severe locoregional silicone granulomatous lymphadenopathy. Poly Implant Prothese silicone implants had been used for bilateral breast augmentation 5 years prior. Extracapsular implant rupture and bilateral axillary lymphadenopathy indicated explantation, capsulectomy, and selective lymph node excision. Histology demonstra...
متن کاملSilicone Breast Implant and Automatic Implantable Cardioverter Defibrillator: Can They Coexist? A Case Report: Erratum
We present a case of a silicone breast implant rupture after insertion of an automatic implantable cardioverter defibrillator (AICD). A 51-year-old woman presented to our plastic surgery clinic to exchange her silicone breast implants. The patient underwent cosmetic mastopexy and breast augmentation in 2008. Because of recurrent myocardial infarctions and chronic heart failure, she underwent an...
متن کاملCapsular Weakness around Breast Implant: A Non-Recognized Complication
Capsular contraction is a frequent complication following breast augmentation. On the other hand, capsular weakness, a not widely recognized complication, may occur around the implant. A weak capsule allows the migration of the prosthesis to the lateral region of the thoracic region or inferiorly, towards the abdomen, due to gravitational forces. The cause of capsular weakness remains unresolve...
متن کاملComparison of breast implant deflation for mentor anterior and posterior valve designs in aesthetic and reconstructive patients.
BACKGROUND Saline breast implant rupture remains problematic after implantation. Company reports and previous studies implicate the valve as a common site of implant failure. This study evaluates the rupture rate of the Mentor posterior valve compared with the anterior valve in breast augmentation and reconstruction. METHODS This is a retrospective analysis of consecutive breast implantations...
متن کاملDual-Energy CT for Evaluation of Intra- and Extracapsular Silicone Implant Rupture
Silicone implants are commonly used for both breast augmentation and breast reconstruction. With aging of the implant, the silicone envelope may become weak or may rupture. The technique of choice for evaluation of implant integrity is breast MRI; however this may be contraindicated in some patients or the cost may be prohibitive. Dual-energy CT allows determination of density and atomic number...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Aesthetic surgery journal
دوره 27 3 شماره
صفحات -