Toric intraocular lens orientation and residual refractive astigmatism: an analysis
نویسندگان
چکیده
PURPOSE To analyze intraocular lens (IOL) orientation data from an online toric back-calculator (astigmatismfix.com) for determining if differences were apparent by lens type. METHODS A retrospective review of astigmatismfix.com toric back-calculations that included IOL identification and intended orientation axis. RESULTS Of 12,812 total validated calculation records, 8,229 included intended orientation and lens identification data. Of the latter, 5,674 calculations (69%) involved lenses oriented 5° or more from their intended position. Using estimated toric lens usage data, the percentage of lenses with orientation ≥5° from intended was 0.89% overall, but the percentage varied significantly between specific toric lens brands (P<0.05). The percentage of back-calculations related to lenses that were not oriented as intended was also statistically significantly different by lens brand (P<0.05). When IOLs were misoriented, they were significantly more likely to be misoriented in a counterclockwise direction (P<0.05). This was found to be due to a bias toward counterclockwise orientation observed with one specific brand, a bias that was not observed with the other three brands analyzed here. CONCLUSION The percentage of eyes with lens orientation ≥5° from intended in the Toric Results Analyzer data set was <1% of toric IOLs in general, with the relative percentage of Tecnis® Toric IOLs significantly higher than AcrySof® Toric IOLs. Both of these had higher rates than the Staar® Toric and Trulign® Toric lenses, with the availability of higher Tecnis and AcrySof cylinder powers a likely contributing factor. The AcrySof Toric IOL appears to be less likely than the Tecnis Toric IOL to cause residual astigmatism as a result of misorientation. The Tecnis Toric IOL appears more likely to be misoriented in a counterclockwise direction; no such bias was observed with the AcrySof Toric, the Trulign® Toric, or the Staar Toric IOLs.
منابع مشابه
Clinical outcomes with toric intraocular lenses planned using an optical low coherence reflectometry ocular biometer with a new toric calculator
PURPOSE To prospectively evaluate postoperative clinical outcomes with implantation of toric intraocular lenses (IOLs) using preoperative keratometry from an optical low coherence reflectometry (OLCR) ocular biometer (Lenstar® LS900) and the built-in Barrett toric calculator. PATIENTS AND METHODS A prospective observational study recruited one or both eyes of subjects who underwent uncomplica...
متن کاملEffects of preoperative corneal astigmatism orientation on results with a low-cylinder-power toric intraocular lens.
PURPOSE To evaluate refractive results with a low-cylinder-power toric intraocular lens (IOL) and the effect of preoperative corneal astigmatism orientation on results. SETTING Private practice, Jackson, Michigan, USA. DESIGN Comparative case series. METHODS This retrospective review of clinical records comprised patients with 0.75 to 1.38 diopters (D) of preoperative corneal astigmatism ...
متن کاملVector analysis of corneal and refractive astigmatism changes following toric pseudophakic and toric phakic IOL implantation.
PURPOSE To determine the efficacy of the astigmatism correction following toric intraocular lens (IOL) and toric phakic IOL (pIOL) implantation in eyes with no previous ocular surgery and in postkeratoplasty (PKP) eyes. In addition, changes in corneal astigmatism were determined. METHODS Astigmatism was analyzed in 35 eyes with an AcrySof toric IOL, 35 eyes with an Artiflex toric pIOL, 50 eye...
متن کاملRotational stability and visual quality in eyes with Rayner toric intraocular lens implantation.
PURPOSE To assess astigmatic reduction and rotational stability of Rayner T-flex toric intraocular lenses (IOL) (573T and 623T; Rayner Intraocular Lenses Ltd) in a series of cataract surgery patients with corneal astigmatism >1.50 diopters (D). METHODS This prospective, observational study included 27 eyes from 22 consecutive patients with pre-operative regular corneal astigmatism ≥1.50 D in ...
متن کاملFoldable toric intraocular lens for astigmatism correction in cataract patients.
PURPOSE To evaluate the results of AcrySof toric intraocular lens (IOL) (Alcon) implantation to correct preexisting astigmatism in patients having cataract surgery. SETTING Ophthalmology Service, Donostia Hospital, San Sebastián, Spain. METHODS This prospective observational study included 30 eyes of 15 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism ...