Maxillary Expansion Via Palatal Mini-Implants: A Preliminary Study
نویسنده
چکیده
Objective: This study evaluates the skeletal and dental effects of a mini-implant supported maxillary expansion (MISME) appliance that applied forces directly to the maxilla. Materials and Method: Records of 9 patients (5 female and 4 male patients; mean age = 12 years 8 months) with indications of maxillary expansion were included in this study. After insertion of four miniscrews (1.6 mm in diameter, 7 mm in length), an acrylic expansion device was bonded on the screws. Two miniscrews were placed in the anterior palate bilaterally, 3–4 mm lateral to the suture and 3–4 mm posterior to the incisive foramen. Two miniscrews were placed bilaterally between the second premolar and first molar roots in the palatal alveolus. The MISME appliance was activated with a semi-rapid protocol until the desired expansion was achieved. The average treatment duration was 97.1 6 62.2 days. Measurements from cephalometric, posteroanterior radiographs and dental casts taken before and after expansion were evaluated statistically. The nonparametric Wilcoxon test was used for not normally distributed parameters (i.e., Nperp-A), and the parametric paired t test was performed for normally distributed parameters. A finding of p , 0.05 was considered to be statistically significant. Results: Forward movement of the maxilla (p,0.05) as well as an increase in nasal and maxillary skeletal and dental widths (p,0.001) were observed in the sample group. Maxillary intermolar, intercanine, and palatal widths also increased (p,0.001) without buccal tipping of molars. A slight posterior rotation of the mandible was seen. Dentoalveolar measurements did not show any significant changes. Conclusion: The MISME appliance showed successful expansion of the maxilla without such side effects as buccal tipping of molars and bite opening. This appliance, which provides parallel expansion, can be a simple and economic alternative to transpalatal distraction. (Turkish J Orthod 2014;27:16–27)
منابع مشابه
Clinical Evaluation of a Direct Method for the Intrusion of Supraerupted Maxillary Molars: A Preliminary Study.
PURPOSE This study aimed to evaluate the use of orthodontic mini-implants for the intrusion of supraerupted maxillary molars. MATERIALS AND METHODS Nine patients were treated using buttons bonded on dental surfaces and mini-implants inserted on the buccal and palatal sides. The intrusion was evaluated by comparing radiographs obtained at the start of treatment and at the end of intrusion. The...
متن کاملIntrusion method for a single overerupted maxillary molar using only palatal mini-implants and partial fixed appliances.
Mandibular first molars are among the most frequently missing teeth in the adult dentition. As a result, the maxillary first molars are frequently overerupted. Conventional approaches to correct this undesirable molar position with skeletal anchorage usually include both buccal and palatal orthodontic mini-implants. Because palatal mini-implants have greater success rates than buccal ones, this...
متن کاملThe efficacy of maxillary protraction protocols with the micro-implant-assisted rapid palatal expander (MARPE) and the novel N2 mini-implant—a finite element study
BACKGROUND Maxillary protraction with the novel N2 mini-implant- and micro-implant-assisted rapid palatal expander (MARPE) can potentially provide significant skeletal effects without surgery, even in older patients where conventional facemask therapy has limited skeletal effects. However, the skeletal effects of altering the location and direction of force from mini-implant-assisted maxillary ...
متن کاملThe effects of micro-implant assisted rapid palatal expansion (MARPE) on the nasomaxillary complex—a finite element method (FEM) analysis
BACKGROUND Orthodontic palatal expansion appliances have been widely used with satisfactory and, most often, predictable clinical results. Recently, clinicians have successfully utilized micro-implants with palatal expander designs to work as anchors to the palate to achieve more efficient skeletal expansion and to decrease undesired dental effects. The purpose of the study was to use finite el...
متن کاملAnalysis of a force system for upper molar distalization using a trans-palatal arch and mini-implant: a finite element analysis study.
The purpose of this study was to analyse distal movements of molars in a force system using a trans-palatal arch (TPA), fixed to the maxillary first molar, and mini-implants placed at the palatal midline, considering the diagnostic standard for placement site in association with variation in upper molar locations, using finite element (FE) analysis. Three-dimensional FE models, divided by the d...
متن کامل