Outcome of Arthroscopic Suture Bridge Technique for Rotator Cuff Tear: Short Term Clinical Outcome In Full-thickness Tear With Fatty Degeneration Less Than Moderate Degree
نویسنده
چکیده
Purpose: We evaluate the short-term clinical outcome of arthroscopic rotator cuff tendon repair with suture-bridge technique in patients with full thickness rotator cuff tear. Materials and Methods: 29 (male:17, female:12) consecutive shoulders treated with this index procedure and early rehabilitation were enrolled. Mean age was 56.4 years (range, 34~73 years) and mean follow-up period was 13 months (range, 12-15 months). Clinical outcomes were evaluated by using the University of California Los Angeles (UCLA) score, the Korean Shoulder Scoring System (KSS) and Visual Analogue Scale (VAS). Postoperative cuff integrity was evaluated through magnetic resonance imaging (MRI) and categorized by Sugaya classification. Results: Postoperative UCLA scores improved from16.4 to 31.6 (p< 0.05) and KSS scores showed 88 at 6 months and 92 at last follow up. Preoperative VAS score was 8.6, which was decreased to 2.1 at 3 months and 1.4 at 6 months postoperatively. 28 patients (96.5%) had increase in range of motion. The follow up MRI was taken in 15 shoulders and the cuff integrity was type I in 6 cases, type II in 7, type III in 1 and type V in 1 by Sugaya classification. Conclusion: Arthroscopic suture-bridge technique resulted in good or excellent clinical outcome in 96.5% of the cases, so we think this technique is one of the reliable procedure for full-thicknes rotator cuff tear.
منابع مشابه
Clinical and Radiological Evaluation after Arthroscopic Rotator Cuff Repair Using Suture Bridge Technique
BACKGROUND We retrospectively assessed the clinical outcomes and investigated risk factors influencing retear after arthroscopic suture bridge repair technique for rotator cuff tear through clinical assessment and magnetic resonance arthrography (MRA). METHODS Between January 2008 and April 2011, sixty-two cases of full-thickness rotator cuff tear were treated with arthroscopic suture bridge ...
متن کاملArthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear
BACKGROUND The purpose of our study is to evaluate the clinical results of arthroscopic suture bridge repair for patients with rotator cuff tears. METHODS Between January 2007 and July 2007, fifty-one shoulders underwent arthroscopic suture bridge repair for full thickness rotator cuff tears. The average age at the time of surgery was 57.1 years old, and the mean follow-up period was 15.4 mon...
متن کاملShort term results of arthroscopic repair of subscapularis tendon tear
Abstract Background: Despite being the largest rotator cuff tendon of the shoulder, the function and clinical relevance of subscapularis pathology has been largely ignored in the literature. Although many studies have focused on subscapularis tears recently, majority of them reported techniques for open repair. The advent of arthroscopy and arthroscopic repair techniques has opened ...
متن کاملArthroscopic repair of complete tear of rotator cuff
Abstract Background: Rotator cuff tear is one of the most common causes of shoulder complaints in the elderly. Based on the severity and patient's condition, a variety of methods applies to manage the tear and surgery is an important method, which could be done by open or arthroscopic technique. The current study aimed to investigate and report short-term results of arthroscopic repair of...
متن کاملAcromio humeral distance less than six millimeter: its meaning in full-thickness rotator cuff tear.
UNLABELLED The present study sought to identify full-thickness rotator cuff tears liable to induce an acromiohumeral distance (AHD) of less than 6 mm. The hypothesis was that, less than 6mm AHD is found exclusively in association with total full-thickness infraspinatus tear. MATERIALS A continuous single-center series recruited 109 shoulders, free of glenohumeral osteoarthritis, presenting wi...
متن کامل