Abstract: A method for calibrating multi-decade inductive voltage dividers has been developed which makes it possible to determine both the inphase and the quadrature error for ratios of i /11, i = 1, 2, ..., 10 in the frequency range from 400 Hz to 5 kHz. Calibration is made by comparing the divider under test against a reference two-stage divider having a ratio winding with 11 identical sections. In calibration of the reference divider itself, an auxiliary 11:1 transformer is used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Design and Self-Calibration of Inductive Voltage Dividers for an Automated Impedance Scaling Bridge

The design and construction of inductive voltage dividers (IVDs) for use in impedance bridge applications in the 50 Hz to 1 MHz frequency range is described. Two dividers are described; one designed to operate from 50 Hz to 2 kHz and the other designed to operate from 2 kHz to 1 MHz. Preliminary comparison results of the new IVDs over the 100 Hz to 50 kHz frequency range are given. A new bridge...

متن کامل

EVALUATION OF INDUCTIVE VOLTAGE DIVIDERS AND 10 nF CAPACITORS IN A CAPACITANCE CALIBRATION METHOD

Researchers within the Quantum Electrical Metrology Division at the National Institute of Standards and Technology (NIST) have implemented a calibration procedure for four-terminal-pair capacitance standards from 0.01 μF to 100 μF [1], [2]. This method depends on the accurate characterization of a 1 nF capacitor and an Inductive Voltage Divider (IVD) 1:10 ratio from 100 Hz to 100 kHz. This pape...

متن کامل

Electronic compensation of inductive voltage dividers and standard voltage transformers

A new compensating system is proposed to reduce the ratio error and the phase error of inductive voltage dividers and standard voltage transformers, operating at no load. An electronic amplifier reduces the input current, which is the main cause of error in low-frequency applications, while at the same time the input impedance is greatly increased.

متن کامل

Dynamic Measurement Uncertainty of Hv Voltage Dividers

− Recently we proposed an approach based on digital filtering for evaluating dynamic non-stationary contributions to the measurement uncertainty. A dynamic simulator instead of a digital filter bank is here utilized for deriving the dynamic measurement uncertainty of mixed capacitive voltage dividers. These are used for lightning impulse measurements, during a calibration measurement of a stand...

متن کامل

Migrating from dc voltage dividers to modern reference multimeters

Until the late 1980’s electrical calibration systems used to compare primary and secondary voltages and resistance standards consisted of several different components. Systems like the Fluke 7105A and the Datron 4900 were the backbone of the majority of electrical calibration laboratories the world over. These systems were specifically combined to provide a traceable source, according to a set ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000