Reference dosimetry on TomoTherapy: an addendum to the 1990 UK MV dosimetry code of practice.
نویسندگان
چکیده
The current UK code of practice for high-energy photon therapy dosimetry (Lillicrap et al 1990 Phys. Med. Biol. 35 1355-60) gives instructions for measuring absorbed dose to water under reference conditions for megavoltage photons. The reference conditions and the index used to specify beam quality require that a machine be able to set a 10 cm × 10 cm field at the point of measurement. TomoTherapy machines have a maximum collimator setting of 5 cm × 40 cm at a source to axis distance of 85 cm, making it impossible for users of these machines to follow the code. This addendum addresses the specification of reference irradiation geometries, the choice of ionization chambers and the determination of dosimetry corrections, the derivation of absorbed dose to water calibration factors and choice of appropriate chamber correction factors, for carrying out reference dosimetry measurements on TomoTherapy machines. The preferred secondary standard chamber remains the NE2611 chamber, which with its associated secondary standard electrometer, is calibrated at the NPL through the standard calibration service for MV photon beams produced on linear accelerators with conventional flattening filters. Procedures are given for the derivation of a beam quality index specific to the TomoTherapy beam that can be used in the determination of a calibration coefficient for the secondary standard chamber from its calibration certificate provided by the NPL. The recommended method of transfer from secondary standard to field instrument is in a static beam, at a depth of 5 cm, by sequential substitution or by simultaneous side by side irradiation in either a water phantom or a water-equivalent solid phantom. Guidance is given on the use of a field instrument in reference fields.
منابع مشابه
Comparison of the recommendations of the AAPM TG‐51 and TG‐51 addendum reference dosimetry protocols
This work quantified differences between recommendations of the TG-51 and TG-51 addendum reference dosimetry protocols. Reference dosimetry was performed for flattened photon beams with nominal energies of 6, 10, 15, and 23 MV, as well as flattening-filter free (FFF) beam energies of 6 and 10 MV, following the recommendations of both the TG-51 and TG-51 addendum protocols using both a Farmer® i...
متن کاملComparison of IPSM 1990 photon dosimetry code of practice with IAEA TRS‐398 and AAPM TG‐51.
Several codes of practice for photon dosimetry are currently used around the world, supported by different organizations. A comparison of IPSM 1990 with both IAEA TRS-398 and AAPM TG-51 has been performed. All three protocols are based on the calibration of ionization chambers in terms of standards of absorbed dose to water, as it is the case with other modern codes of practice. This comparison...
متن کاملIonization chamber dosimetry of small photon fields: a Monte Carlo study on stopping-power ratios for radiosurgery and IMRT beams.
Absolute dosimetry with ionization chambers of the narrow photon fields used in stereotactic techniques and IMRT beamlets is constrained by lack of electron equilibrium in the radiation field. It is questionable that stopping-power ratio in dosimetry protocols, obtained for broad photon beams and quasi-electron equilibrium conditions, can be used in the dosimetry of narrow fields while keeping ...
متن کاملA study on needed or unneeded ReDosimetry and Recomissioning of a linac with Add on MLC by Comparing Dosimetric Data
Introduction: Today different uses of multileaf collimators(MLC) in different techniques of radiotherapy are common. Due to the use of this facility it is possible to have maximum radiation dose to target volumes and minimum radiation dose to critical tissues surronding treatment volumes. But there are numerouse Linear accelerators in IRAN without MLC. Because of high price of...
متن کاملPre-treatment and in-vivo dosimetry of Helical Tomotherapy (HT) treatment plans by using the Dosimetry Check system coupled to HT detectors
Purpose: In radiotherapy, the proper way to ensure that the dose delivered to a patient is correct and strongly agree with that simulated by his treatment plan currently requires a pre-treatment dosimetric verification. Although this procedure can be realised by using a combined detectorphantom system to monitor the patient plan dose delivered on a phantom, the quality of the entire treatment c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Physics in medicine and biology
دوره 59 6 شماره
صفحات -
تاریخ انتشار 2014