چکیده

The increasing prevalence of end ‐stage chronic kidney disease associated with advances in treatment is expected to lead to improved survival rates of chronic haemodialysis patients in Portugal. Establishing and maintaining vascular access patency is becoming a challenging issue in these patients. We present a case report of a multiple vascular access failure patient to whom a novel vascular access device was implanted which allowed successful haemodialysis, despite the presence of central venous stenosis and/or occlusion. To our knowledge the present case report describes the first utilization of Hemodialysis Reliable Outflow (HeRO) Graft device in Portugal. We present the case as well as a brief description of the device and available literature. This case report also under‐ lines the importance of adopting a multidisciplinary approach in order to overcome complex and life ‐threatening clinical challenges.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety and efficacy of a modified HeRO dialysis device in achieving early graft cannulation: A single-institution experience

Hemodialysis Reliable Outflow (HeRO) grafts (Merit Medical Systems, Inc, South Jordan, Utah) provide a means for access in catheter-dependent hemodialysis patients but typically require several weeks for tissue incorporation. Modifying the HeRO graft with an ACUSEAL graft (W. L. Gore & Associates, Newark, Del) can allow immediate cannulation, thus reducing catheter dependence time and its assoc...

متن کامل

Alternative Strategies for Central Venous Stenosis and Occlusion in Patients Requiring Haemodialysis Access.

Dear Editor, The use of tunnelled dialysis catheters (TDCs) in patients awaiting permanent dialysis access creation has resulted in a rise in the prevalence of central venous stenosis and occlusion (CVSO) in up to 50% of cases.1,2 CVSO is a difficult problem to manage. The mainstay of treatment for CVSO includes percutaneous transluminal angioplasty (PTA) and stenting. These are, however, prone...

متن کامل

Salvaging vascular access and treatment of severe limb edema: case reports on the novel use of the hemodialysis reliable outflow vascular access device.

We report two cases in which patients on chronic hemodialysis presented with morbid unilateral edema of the upper extremity and chest on the side of a currently functioning arteriovenous access. Both patients were known to the vascular surgery service and had previously undergone multiple attempts to create and maintain vascular access. Both severe and disabling edema and the need to maintain d...

متن کامل

Tesio catheters: findings in post-mortem examination.

Vascular access is still the 'Achilles heel' in the haemodialysis treatment. Access-related problems account for approximately 25% of hospitalizations in haemodialysis patients. In patients lacking a suitable vascular anatomy or presenting repeated a-v fistula thrombosis due to vascular problems and/or hypotension, a permanent central venous catheter can establish a reliable long-term vascular ...

متن کامل

Primary and secondary patencies of transposed femoral vein fistulas are significantly greater than with the HeRO graft.

INTRODUCTION For access-challenged patients with bilateral upper extremity central venous stenosis, solutions include the Hemodialysis Reliable Outflow (HeRO) device or an autogenous AV fistula in the lower limb. We evaluated HeRO grafts and transpositions of the femoral vein in maintaining primary and secondary patency. METHODS We retrospectively analyzed 40 patients with a HeRO device and 1...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016