PURPOSE A ghost correction strategy for Simultaneous Multi-Slice (SMS) EPI methods that provides improved ghosting artifact reduction compared to conventional methods is presented. Conventional Nyquist ghost correction methods for SMS-EPI rely on navigator data that contain phase errors from all slices in the simultaneously acquired slice-group. These navigator data may contain spatially nonlinear phase differences near regions of B0 inhomogeneity, which violates the linear model employed by most EPI ghost correction algorithms, resulting in poor reconstructions. METHODS Dual-Polarity GRAPPA (DPG) was previously shown to accurately model and correct both spatially nonlinear and 2D phase errors in conventional single-slice EPI data. Here, an extension we call Dual-Polarity slice-GRAPPA (DPsG) is adapted to the slice-GRAPPA method and applied to SMS-EPI data for slice separation and ghost correction concurrently-eliminating the need for a separate ghost correction step while also providing improved slice-specific EPI phase error correction. RESULTS Images from in vivo SMS-EPI data reconstructed using DPsG in place of conventional Nyquist ghost correction and slice-GRAPPA are presented. DPsG is shown to reduce ghosting artifacts and provide improved temporal SNR compared to the conventional reconstruction. CONCLUSION The proposed use of DPsG for SMS-EPI reconstruction can provide images with lower artifact levels, higher image fidelity, and improved time-series stability compared to conventional reconstruction methods.
منابع مشابه
Dual-Polarity GRAPPA for simultaneous reconstruction and ghost correction of EPI data
Purpose: We seek improved image quality from accelerated EPI data, particularly at ultra-high field. Certain artifacts in EPI reconstructions can be attributed to nonlinear phase differences between data acquired using frequency encoding gradients of alternating polarity. These errors appear near regions of local susceptibility gradients, and typically cannot be corrected with conventional Nyqu...
متن کاملEvaluation of 2D multiband EPI imaging for high-resolution, whole-brain, task-based fMRI studies at 3T: Sensitivity and slice leakage artifacts
Functional magnetic resonance imaging (fMRI) studies that require high-resolution whole-brain coverage have long scan times that are primarily driven by the large number of thin slices acquired. Two-dimensional multiband echo-planar imaging (EPI) sequences accelerate the data acquisition along the slice direction and therefore represent an attractive approach to such studies by improving the te...
متن کاملWideband Parallel Imaging
Human lower limb images were successfully acquired with an acceleration rate of up to 8x by using wideband parallel imaging. The non-uniform multislice profile problem of this technique was successfully compensated to enhance the image quality of the outer slices. Also the signal-to-noise ratio (SNR) of this ultra fast imaging technique, wideband parallel imaging, was verified to be similar wit...
متن کاملOptimized co-registration method of Spinal cord MR Neuroimaging data analysis and application for generating multi-parameter maps
Introduction: The purpose of multimodal and co-registration In MR Neuroimaging is to fuse two or more sets images (T1, T2, fMRI, DTI, pMRI, …) for combining the different information into a composite correlated data set in order to visualization, re-alignment and generating transform to functional Matrix. Multimodal registration and motion correction in spinal cord MR Neuroimag...
متن کاملSimultaneous multi-slice excitation by parallel transmission using a dual-row pTX head array
Introduction Simultaneous multi-slice (SMS) imaging with receiver arrays allows for greatly accelerated 2D single-shot acquisitions with BOLD or diffusionweighted EPI (1-4), and spirals (5). The commonly used SMS excitation methods require specially designed multi-band (MB) (1,2) or PINS RF pulses (6) to excite N slices. In this abstract we explore the use of parallel transmission (pTX) for SMS...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره شماره
صفحات -
تاریخ انتشار 2018