European Xfel-linac Two-phase He Ii Flow Simulations

نویسندگان

  • V.Gubarev
  • B.Petersen
چکیده

The superconducting 1.3-GHz niobium cavities of the XFEL linear accelerator will be cooled in a bath of saturated liquid He II at a temperature of 2 K. The liquid He II supply of the 1.7-km long linac is subdivided in sections of about 150 m length. In these sections a two-phase flow of He II liquid and corresponding vapor occurs. A stable stratified smooth helium flow has to be maintained for the RF operation of the cavities, to avoid any vibrations or microphonic effects. A computer code has been developed to simulate the two-phase flow patterns in the XFEL-linac, based on an existing model. The flow characteristics at different cryogenic loads and helium temperatures have been calculated. The results are shown and the consequences for the design of the XFEL-linac cryogenic system are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Linac Coherent Light Source II (LCLS II) at SLAC

The Linac Coherent Light Source (LCLS) will be the world’s first free-electron laser at Ångström wavelengths (XFEL). It will be the first high brightness hard x-ray source with full transverse coherence. Its average brightness will exceed that of the brightest existing x-ray sources by a factor of 100 and its peak brightness will exceed them by a factor of ten billion. Its ultra-fast pulse stru...

متن کامل

Energy-Recovery Option for a Future X-ray Free-Electron Laser

A superconducting electron linac together with an energy-recovery system, which has been demonstrated as a useful driver for high-power IR-FELs, seems to be an attractive device for a future X-ray FEL facility as well, because the energy-recovery enable one to reduce the RF generator power required for the operation and also reduce the radiation from the beam dump. Automatic cancellation of bea...

متن کامل

Prospects for CW and LP operation of the European XFEL in hard X-ray regime

The European XFEL will operate nominally at 17.5 GeV in SP (short pulse) mode with 0.65 ms long bunch train and 10 Hz repetition rate. A possible upgrade of the linac to CW (continuous wave) or LP (long pulse) modes with a corresponding reduction of electron beam energy is under discussion since many years. Recent successes in the dedicated R&D program allow to forecast a technical feasibility ...

متن کامل

Status of the Re-entrant Cavity Beam Position Monitor for the European Xfel Project

The European XFEL is a research facility, currently under construction in Germany. It is based on a superconducting electron linac including about 100 cryomodules based on the TESLA technology. Each cryomodule is equipped with a beam position monitor connected to a quadrupole at the high-energy end of the cavity string. Around one third of cold BPMs will be reentrant RF cavities. This contribut...

متن کامل

Perspectives for imaging single protein molecules with the present design of the European XFEL

The Single Particles, Clusters and Biomolecules & Serial Femtosecond Crystallography (SPB/SFX) instrument at the European XFEL is located behind the SASE1 undulator and aims to support imaging and structure determination of biological specimen between about 0.1 μm and 1 μm size. The instrument is designed to work at photon energies from 3 keV up to 16 keV. Here, we propose a cost-effective proo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008