Constructing a new optical sensor for monitoring ammonia in water samples using bis(acetylacetoneethylendiamine)-tributylphosphin cobalt(III) tetraphenylborate complex-coated triacetylcellulose.

نویسندگان

  • Ghodratollah Absalan
  • Mohammad Soleimani
  • Mozaffar Asadi
  • Mohammad Bagher Ahmadi
چکیده

A new ammonia optical sensor was designed using bis(acetylacetoneethylendiamine)tributylphosphin cobalt(III) tetraphenylborate complex, coated on transparent triacetylcellulose film as membrane. The change in the absorbance of the optode at the maximum wavelength of 408 nm was related to ammonia concentration in aqueous samples. A buffer solution with a pH of 9 (sodium borate-HCl) was used. The optode was fully regenerated in pH 2. The linear dynamic range for determination of ammonia was 3.3 x 10(-4) to 6.9 x 10(-3) mol l(-1) with a detection limit of 5.0 x 10(-5) mol l(-1) and a response time range of 4 - 6 min. This membrane was successfully applied for determination of ammonia in drinking water.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Evaluation of a Novel Bismuth Optical Sensor Using PC-ANN Application

The characterization of and construction of a new optical sensor based on the immobilization of Pyrocatechol Violet on a triacetylcellulose membrane was described to for the determination of bismuth (III) in real samples. The interaction between sensing membrane and bismuth (III) was caused at pH 3.80 in acetate buffer solution and the color changed from yellow to blue along with the appearance...

متن کامل

Design novel optical sensor for determination of bismuth based on immobilization of 4-(4-nitrophenyl)-1-naphthol on a triacetylcellulose membrane

A novel optical sensor has been proposed for sensitive determination of bismuth ion basedon immobilization of 4-(4-nitrophenylazo)-1-naphthol on a triacetylcellulose membrane.Chemical binding of bismuth ions in solution with a 4-(4-nitrophenylazo)-1-naphtholimmobilized on the triacetylcelluse surface could be monitored spectrophotometrically. Theoptode shows excellent response over wide concent...

متن کامل

Comparison of new optical sensor based on triazene ligand immobilized on PVC and triacetylcellulose membranes for Hg (II) Ion

For spectrophotometric analysis of Hg (II) ions, we have used and compared two membranes preparation methods using different polymer; one is poly(vinyl chloride) (PVC) and the other is triacetylcellulose (TAC). In the case of TAC membrane, it was treated with a ligand solution (1.166 × 10-3 mole L-1) in ethylenediamine at the ambient temperature for almost 2-5 min. However, in the case of PVC m...

متن کامل

New Coated Graphite Potentiometric Sensor for Selective Determination of Copper (II) Ions

A highly selective copper (II) coated graphite sensor was prepared by 1,13-bis(8-quinolyl)- 1,4,7,10,13-pentaoxatridecane (kryptofix 5) as a supramolecule ionophore into plasticized polyvinyl chloride (PVC) membrane. The best response characteristic was observed using the membrane composition of PVC = 30.0 mg, dioctyl sebacate (DOS) = 63.5 mg, palmitic acid (PA) = 3.0 mg and kryptofix 5 = 3.5 m...

متن کامل

An Optical Fiber Sensor Probe Using a PMMA/CPR Coated Bent Optical Fiber as a Transducer for Monitoring Trace Ammonia

Ammonia sensors have broad spectrum of applications for industrial process control as well as for environmental monitoring. An optical fiber ammonia sensor probe has been developed by using a bent optical fiber having dual poly(methyl methacrylate) (PMMA)/chlorophenol red (CPR) coatings as a transducer. This sensor probe was tested for monitoring trace ammonia in gas samples using air as sample...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 20 10  شماره 

صفحات  -

تاریخ انتشار 2004