Imaging dispersion of myocardial repolarization, I: comparison of body-surface and epicardial measures.

نویسندگان

  • J E Burnes
  • R N Ghanem
  • A L Waldo
  • Y Rudy
چکیده

BACKGROUND Body-surface ECG measures (QT dispersion [QTd], QRST integrals) have been used as indices of myocardial repolarization abnormalities with the goal of identifying patients at risk of fatal arrhythmias. The clinical utility of these measures has been questioned. We investigate the complex relationship between epicardial and body-surface potentials in the context of regionally abnormal myocardial repolarization. METHODS AND RESULTS Epicardial potentials were recorded with a 224-electrode sock from an open-chest dog during control, regional epicardial warming, cooling, and adjacent warming and cooling to induce localized alterations in myocardial repolarization and regions of increased repolarization dispersion. Body-surface potentials were generated from these epicardial potentials in a human torso model. Epicardial estimates of repolarization (activation recovery intervals [ARIs] and QRST integrals) were evaluated for their ability to identify regions with increased repolarization dispersion. Body-surface QRST integrals and QTd in 12-lead ECG and 64-lead body-surface potential maps were evaluated for their ability to detect increased dispersion of myocardial repolarization. Epicardial ARI and QRST integral maps successfully located epicardial regions with increased dispersion of repolarization. The increased dispersion was not consistently reflected in the 12-lead or 64-lead ECG QTd or in the body-surface QRST integral maps. CONCLUSIONS This study demonstrates the inadequacy of body-surface measures that are thought to reflect myocardial dispersion of repolarization. In contrast, measures based on epicardial electrograms (ARI or epicardial QRST integral maps) provide physiologically relevant information about myocardial repolarization and can locate regions of increased dispersion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Body-Surface and Epicardial Measures

Background—Body-surface ECG measures (QT dispersion [QTd], QRST integrals) have been used as indices of myocardial repolarization abnormalities with the goal of identifying patients at risk of fatal arrhythmias. The clinical utility of these measures has been questioned. We investigate the complex relationship between epicardial and body-surface potentials in the context of regionally abnormal ...

متن کامل

Imaging dispersion of myocardial repolarization, II: noninvasive reconstruction of epicardial measures.

BACKGROUND Dispersion of myocardial repolarization supports the development and maintenance of life-threatening arrhythmias. Current noninvasive approaches for detecting substrates with increased dispersion based on ECG measures (eg, QT dispersion) have shown limited success and inconsistencies. The companion article shows that, in contrast, epicardial potentials and derived measures reflect lo...

متن کامل

Noninvasive Reconstruction of Epicardial Measures

Background—Dispersion of myocardial repolarization supports the development and maintenance of life-threatening arrhythmias. Current noninvasive approaches for detecting substrates with increased dispersion based on ECG measures (eg, QT dispersion) have shown limited success and inconsistencies. The companion article shows that, in contrast, epicardial potentials and derived measures reflect lo...

متن کامل

Imaging electrocardiographic dispersion of depolarization and repolarization during ischemia: simultaneous body surface and epicardial mapping.

BACKGROUND Myocardial ischemia creates abnormal electrophysiological substrates that result in life-threatening ventricular arrhythmias. Identifying patients at risk of such abnormalities by use of body surface electrical measures is controversial. We investigated the sensitivity of torso measures, recorded simultaneously with epicardial electrograms, to changes in dispersion of depolarization ...

متن کامل

QT-Dispersion as a potential marker in prognosis of acute myocardial infarction

Introduction: QT dispersion in a 12 lead ECG represents the heterogeneity of ventricular repolarization. The prolongation of QT-interval dispersion increases the risk of coronary heart disease, ventricular arrhythmia, and sudden cardiac death in patients with myocardial infarction. We aimed to investigate the prognostic value of QT-dispersion in patients with acute myocardial infarction. Meth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 104 11  شماره 

صفحات  -

تاریخ انتشار 2001