INTRODUCTION Metal-on-metal hip articulations have been intensely debated after reports of adverse reactions and high failure rates. The aim of this study was to retrospectively evaluate the implant of a metal-on.metal total hip articulation (MOM THA) from a single manufacture in a two-center study. MATERIALS AND METHODS 108 CONSERVE(®) MOM THA were implanted in 92 patients between November 2005 and December 2010. Patients had at time of retrospective evaluation their journals reviewed for re-operations and adverse reactions. RESULTS 20 hips were re-operated (18.4%) at a mean follow up of 53 months. 4 pseudotumors were diagnosed at time of follow up but no substantiated link was made between adverse reactions and re-operations. CONCLUSION The high re-operation rates found in this study raised concern about the usage of the MOM THA and subsequently lead to the termination of implantation of this MOM THA at the two orthopaedic departments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Elevated Cobalt, Chromium and Molybdenum Levels in Peripheral Blood Have No Effect on the Development of Heterotopic Ossifications after Metal-on-Metal Total Hip Arthroplasty

Metal debris from metal-on-metal (MoM) total hip arthroplasties (THA) has been suspected to cause periprosthetic heterotopic ossifications (HO). We determined the influence of disseminated cobalt, chromium and molybdenum on the development of HO. Native blood samples from patients with 86 high-carbon and 16 low-carbon Co28Cr6Mo articulations were analysed by highresolution inductively coupled p...

متن کامل

The clinical performance of metal-on-metal as an articulation surface in total hip replacement.

The metal-on-metal articulations in total hip arthroplasty (THA) were widely used between 1960 and 1975. The McKee-Farrar and other first-generation prostheses failed at a high rate because impingement caused early component loosening. The problem of early component loosening was corrected by improved component design and better manufacturing quality. Second-generation metal-on-metal total hip ...

متن کامل

Metal in Total Hip Arthroplasty: Wear Particles, Biology, and Diagnosis.

Total hip arthroplasty (THA) has been performed for nearly 50 years. Between 2006 and 2012, more than 600,000 metal-on-metal THA procedures were performed in the United States. This article reviews the production of metal wear debris in a metal-on-metal articulation and the interaction of cobalt and chromium ions that ultimately led to a dramatic decline in the use of metal-on-metal THA articul...

متن کامل

Metal ion levels after metal-on-metal Ring total hip replacement: a 30-year follow-up study.

Metal-on-metal bearings for total hip replacement (THR) are becoming increasingly popular. Improved wear characteristics mean that these articulations are being inserted into younger patients in the form of THR and resurfacing procedures. This has led to concerns regarding potential carcinogenicity because of the increased exposure to metal ions that the procedure brings. We have studied the se...

متن کامل

Metal-on-metal vs conventional total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials.

Metal-on-metal (MOM) hip articulations represent a potential alternative to conventional metal-on-polyethylene total hip arthroplasty (THA). We performed a systematic review of the peer-reviewed literature in search of studies comparing MOM with conventional primary THA with regard to functional outcomes, radiographic outcomes, and complication rates. Four Level I randomized controlled trials r...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The open orthopaedics journal

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016