Comparison of Modified Shuffled Frog Leaping Algorithm and Other Heuristic Methods for Optimal Placement of Unified Power Flow Controllers in Electrical Power Systems
نویسندگان
چکیده
This paper presents a Modified Shuffled Frog Leaping Algorithm to obtein the optimal number and location of FACTS devices in a power system. Unified Power Flow Controller (UPFC) has great flexibility that can control the active and reactive power flow and bus voltages, simultaneously. Decoupled model of the UPFC is applied to maximize the system loadability subject to the transmission line capacity limits and speciWed voltage level. Shuffled frog-leaping algorithm (SFLA) is a new memetic meta heuristic algorithm with efficient mathematical function and global search capability. The objective is to maximize the transmission system loadability subject to the transmission line capacity limits and specified bus voltage levels. Using the proposed method, the location of UPFCs and their parameters are optimized simultaneously. The proposed approach is examined and tested on IEEE 14-bus system and IEEE 118-bus system. The results show that the steady state performance of power system can be effectively enhanced due to the optimal location and parameters of the UPFC.
منابع مشابه
Combined Heat and Power Economic Dispatch using Improved Shuffled Frog Leaping Algorithm
Recently, Combined Heat and Power (CHP) systems have been utilized increasingly in power systems. With the addition penetration of CHP-based co-generation of electricity and heat, the determination of economic dispatch of power and heat becomes a more complex and challenging issue. The optimal operation of CHP-based systems is inherently a nonlinear and non-convex optimization problem with a lo...
متن کاملOptimal Reconfiguration and Capacitor Allocation in Radial Distribution Systems Using the Hybrid Shuffled Frog Leaping Algorithm in the Fuzzy Framework
In distribution systems, in order to diminish power losses and keep voltage profiles within acceptable limits, network reconfiguration and capacitor placement are commonly used. In this paper, the Hybrid Shuffled Frog Leaping Algorithm (HSFLA) is used to optimize balanced and unbalanced radial distribution systems by means of a network reconfiguration and capacitor placement. High accuracy and ...
متن کاملUsing the Modified Shuffled Frog Leaping Algorithm for Optimal Sizing and location of Distributed Generation Resources for Reliability Improvement
Restructuring the recent developments in the power system and problems arising from construction as well as the maintenance of large power plants lead to increase in using the Distributed Generation (DG) resources. DG units due to its specifications, technology and location network connectivity can improve system and load point reliability indices. In this paper, the allocation and sizing of di...
متن کاملOptimal Placement of Unified Power Flow Controller in Power System by a New Advanced Heuristic Method
This paper presents a Shuffled Frog Leaping Algorithm to seek the optimal number and location of FACTS devices in a power system. Unified Power Flow Controller (UPFC) has great flexibility that can control the active and reactive power flow and bus voltages, simultaneously. Decoupled model of the UPFC is applied to maximize the system loadability subject to the transmission line capacity limits...
متن کاملVoltage Flicker Parameters Estimation Using Shuffled Frog Leaping Algorithm and Imperialistic Competitive Algorithm
Measurement of magnitude and frequency of the voltage flicker is very important for monitoring andcontrolling voltage flicker efficiently to improve the network power quality. This paper presents twonew methods for measurement of flicker signal parameters using Shuffled Frog Leaping Algorithm(SFLA) and Imperialist Competitive Algorithm (ICA). This paper estimates fundamental voltage andflicker ...
متن کامل