Screw Placement Accuracy and Outcomes Following O-Arm-Navigated Atlantoaxial Fusion: A Feasibility Study

نویسندگان

  • Jacob D. Smith
  • Megan M. Jack
  • Nicholas R. Harn
  • Judson R. Bertsch
  • Paul M. Arnold
چکیده

Study Design Case series of seven patients. Objective C2 stabilization can be challenging due to the complex anatomy of the upper cervical vertebrae. We describe seven cases of C1-C2 fusion using intraoperative navigation to aid in the screw placement at the atlantoaxial (C1-C2) junction. Methods Between 2011 and 2014, seven patients underwent posterior atlantoaxial fusion using intraoperative frameless stereotactic O-arm Surgical Imaging and StealthStation Surgical Navigation System (Medtronic, Inc., Minneapolis, Minnesota, United States). Outcome measures included screw accuracy, neurologic status, radiation dosing, and surgical complications. Results Four patients had fusion at C1-C2 only, and in the remaining three, fixation extended down to C3 due to anatomical considerations for screw placement recognized on intraoperative imaging. Out of 30 screws placed, all demonstrated minimal divergence from desired placement in either C1 lateral mass, C2 pedicle, or C3 lateral mass. No neurovascular compromise was seen following the use of intraoperative guided screw placement. The average radiation dosing due to intraoperative imaging was 39.0 mGy. All patients were followed for a minimum of 12 months. All patients went on to solid fusion. Conclusion C1-C2 fusion using computed tomography-guided navigation is a safe and effective way to treat atlantoaxial instability. Intraoperative neuronavigation allows for high accuracy of screw placement, limits complications by sparing injury to the critical structures in the upper cervical spine, and can help surgeons make intraoperative decisions regarding complex pathology.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computer-Aided Surgery Does Not Increase the Accuracy of Dorsal Pedicle Screw Placement in the Thoracic and Lumbar Spine: A Retrospective Analysis of 2,003 Pedicle Screws in a Level I Trauma Center

Study Design A retrospective analysis of a prospective database. Objective Meta-analyses suggest that computer-assisted systems can increase the accuracy of pedicle screw placement for dorsal spinal fusion procedures. The results of further meta-analyses report that in the thoracic spine, both the methods have comparable placement accuracy. These studies are limited due to an abundance of screw...

متن کامل

Role of the O-arm and Computer-assisted Navigation of Safe Screw Fixation in Children with Traumatic Rotatory Atlantoaxial Subluxation

STUDY DESIGN A retrospective analysis of 7 patients with traumatic rotatory atlanto-axial subluxation. OVERVIEW OF LITERATURE Cases of traumatic rotatory atlantoaxial subluxation in children are difficult to be stabilized. Surgical challenges include: narrow pedicles, medial vertebral arteries, vertebral artery anomalies, fractured pedicles or lateral masses, and fixed subluxation. The use of...

متن کامل

Prospective, Self-controlled, Comparative Study of Transposterior Arch Lateral Mass Screw Fixation and Lateral Mass Screw Fixation of the Atlas in the Treatment of Atlantoaxial Instability.

STUDY DESIGN A prospective self-controlled study. OBJECTIVE The aim of the present study was to compare the application and clinical outcomes of transposterior arch lateral mass screw and lateral mass screw fixation of the atlas in the treatment of atlantoaxial instability. SUMMARY OF BACKGROUND DATA Atlas posterior screw fixation techniques comprise transposterior arch lateral mass screw f...

متن کامل

The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study

OBJECTIVES The transoral atlantoaxial reduction plate system treats irreducible atlantoaxial dislocation from transoral atlantoaxial reduction plate-I to transoral atlantoaxial reduction plate-III. However, this system has demonstrated problems associated with screw loosening, atlantoaxial fixation and concealed or manifest neurovascular injuries. This study sought to design a set of individual...

متن کامل

Transarticular screw fixation for atlantoaxial instability - modified Magerl's technique in 38 patients

BACKGROUND Symptomatic atlantoaxial instability needs stabilization of the atlantoaxial joint. Among the various techniques described in literature for the fixation of atlantoaxial joint, Magerl's technique of transarticular screw fixation remains the gold standard. Traditionally this technique combines placement of transarticular screws and posterior wiring construct. The aim of this study is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016