Respiratory Rate is a Valid and Reliable Marker for the Anaerobic Threshold: Implications for Measuring Change in Fitness.
نویسندگان
چکیده
The anaerobic threshold (AT) has been defined as the theoretical highest exercise level that can be maintained for prolonged periods. It is of practical importance to the competitive endurance athlete to measure progress and plan training programs. The primary objective of this study was to assess the reliability and validity of breakpoint in the respiratory rate (RR) during incremental exercise as a marker for the AT. Secondary objectives were 1) to assess the reliability of the ventilatory threshold (VE) and ventilatory equivalent (VE/VO2) breakpoint, and 2) to assess differences in these 3 methods for their potential to measure change in fitness, as measured by standard error of measurement (SEM), coefficient of variability (CV), and correlation coefficient (R). Fifteen competitive male cyclists (5 category II, 6 category III, 1 category IV, 3 category V United States Cycling Federation) completed 2 maximal oxygen consumption tests within one week on an electronically braked cycle ergometer. A repeated measures Analysis of Variance using 2x3 design (test and methods) resulted in no significant differences (F = 0.02, p = 0.978), indicating that 1)all 3 methods are reproducible, and 2) RR, when compared to VE and VE/VO2, is a valid method of assessing the anaerobic threshold. The lowest SEM, lowest CV and highest R were obtained with the VE method (SEM = 19.4 watts, CV = 6.7%, R = 0.872), compared to VE/VO2 (SEM = 21.5 watts, CV = 7.4%, R=.811) and RR (SEM = 35.3 watts, CV = 12.2%, R = 0.800). From the results of this study, it is concluded that the RR method is a valid and reliable method for detecting AT. However, due to the relatively high SEM and CV, and low R, when compared to VE and VE/VO2, its insensitivity to small changes seen in highly fit athletes would preclude its use in measuring changes in AT. It appears that either VE or VE/VO2 would be appropriate for measuring AT changes in highly fit athletes. Key PointsRespiratory rate is a valid and reliable marker of the anaerobic threshold.Due to a relatively high standard error of measurement and coefficient of variability for the respiratory rate method, use of ventilation (VE) and ventilatory equivalent for oxygen (VE/VO2 is preferred when assessing changes in anaerobic threshold.When assessing changes in maximal aerobic capacity, maximal watts has a lower standard error of measurement and coefficient of variability and is preferred over changes in maximal oxygen consumption.
منابع مشابه
The Relationship between Translation Tests and Reading Comprehension: A Case of Iranian University Students
The present study seeks to investigate the potentiality of the translation task as a testing method for measuring reading comprehension. To achieve this objective, two types of translation tests, open-ended and multiple-choice tests, and two types of reading comprehension tests, multiple-choice reading comprehension and open-ended cloze tests were developed in this study. The reliability of the...
متن کاملImpact of CrossFit Exercise on Different Aspects of Physical Fitness, with Emphasis on Military Fitness: A Review Article
Background and Aim: CrossFit is an exercise program designed to provide general and inclusive physical fitness and improves fitness in all 10 areas including cardiovascular and respiratory endurance, muscle endurance and strength, power, flexibility, speed, coordination and agility. This is especially important for the military population, which needs to be better prepared to respond to specifi...
متن کاملThe Effect of Quadriceps Kinesio Taping on the Anaerobic Muscle Power and Anaerobic Threshold of ََActive Male Students
Introdution: The Purpose of this study examined the effect of Kinesio taping the quadriceps femurs muscle of active students on anaerobic muscle power (AMP) and the anaerobic threshold (AT) to analyze the functional value of taping on athletic performance capacity. Methods: Twenty eight male healthy students with a mean age of 22.02±2.2 years were enrolled in this study voluntarily and randoml...
متن کاملModelling Anaerobic Digestion of Cow Manure to Predict Methane Flow Rate
Anaerobic digestion (AD) of biowastes is one of the most common ways to produce methane-rich biogas, which has considerable potential to replace the fossil fuel used in multiple applications, such as vehicular transportation, internal combustion engines, cogeneration of heat and power systems and many other systems. Many companies are involved in the design and construction of anaerobic digesti...
متن کاملValidity of the modified conconi test for determining ventilatory threshold during on-water rowing.
The objectives of this study were to design a field test based on the Conconi protocol to determine the ventilatory threshold of rowers and to test its reliability and validity. A group of sixteen oarsmen completed a modified Conconi test for on-water rowing. The reliability of the detection of the heart rate threshold was evaluated using heart rate breaking point in the Conconi test and retest...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of sports science & medicine
دوره 4 4 شماره
صفحات -
تاریخ انتشار 2005