An elbow extension neuroprosthesis for individuals with tetraplegia.
نویسندگان
چکیده
Functional electrical stimulation (FES) of the triceps to restore control of elbow extension was integrated into a portable hand grasp neuroprosthesis for use by people with cervical level spinal cord injury. An accelerometer mounted on the upper arm activated triceps stimulation when the arm was raised above a predetermined threshold angle. Elbow posture was controlled by the subjects voluntarily flexing to counteract the stimulated elbow extension. The elbow moments created by the stimulated triceps were at least 4 N.m, which was sufficient to extend the arm against gravity. Electrical stimulation of the triceps increased the range of locations and orientations in the workspace over which subjects could grasp and move objects. In addition, object acquisition speed was increased. Thus elbow extension enhances a person's ability to grasp and manipulate objects in an unstructured environment.
منابع مشابه
Restoration of elbow extension via functional electrical stimulation in individuals with tetraplegia.
Functional electrical stimulation of the triceps is a method of restoring elbow extension to individuals with paralyzed triceps. Eleven arms of individuals with cervical-level spinal cord injuries (SCIs) received a triceps electrode as an addition to a hand-grasp neuroprosthesis. Stimulation was controlled either as part of a preprogrammed pattern or via a switch or an accelerometer that was co...
متن کاملA transducer to measure isometric elbow moments.
OBJECTIVE The purpose of this study was to design and implement a transducer to measure accurately the isometric elbow moments produced by individuals with tetraplegia. DESIGN The device needed to be insensitive to off-axis moments and proximal joint motions and be capable of being used over a wide range of elbow and shoulder positions in an outpatient clinic setting. BACKGROUND Measurement...
متن کاملSimulated neuroprosthesis state activation and hand-position control using myoelectric signals from wrist muscles.
This paper reports on the initial phase of feasibility testing of a control strategy that uses myoelectric signals (MES) from wrist flexor and extensor muscles to control a hand-grasp neuroprosthesis for C7 tetraplegia. The control strategy was customized to the MES patterns produced during wrist flexion, extension, and relaxation for five able-bodied subjects and two individuals with C7 spinal...
متن کاملPreliminary performance of a surgically implanted neuroprosthesis for standing and transfers--where do we stand?
This paper describes the preliminary performance of a surgically implanted neuroprosthesis for standing and transfers after spinal cord injury (SCI) in an initial group of 12 volunteers with longstanding paralysis. The CWRU/VA standing neuroprosthesis consists of an 8-channel implanted receiver-stimulator, epimysial and surgically implanted intramuscular electrodes, and a programmable wearable ...
متن کاملComparison of wrist and elbow stabilization following pinch reconstruction in tetraplegia.
PURPOSE Individuals with spinal cord injuries resulting in tetraplegia may receive tendon transfer surgery to restore grasp and pinch function. These procedures often involve rerouting the brachioradialis (Br) and the extensor carpi radialis longus tendons volar to the flexion-extension axis of the wrist, leaving the extensor carpi radialis brevis (ECRB) muscle to provide wrist extension streng...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society
دوره 6 1 شماره
صفحات -
تاریخ انتشار 1998