Meta-analysis of valve hemodynamics and left ventricular mass regression for stentless versus stented aortic valves.
نویسندگان
چکیده
BACKGROUND Stentless aortic bioprostheses have been advocated as being superior to conventional bioprosthetic valves, with benefits including superior left ventricular mass regression and larger effective orifice area. Several high-quality randomized studies now exist on this topic, and we sought to summarize them by meta-analysis. METHODS The literature was searched from 1995 to 2006, in MEDLINE, EMBASE, CRISP, metaRegister of Controlled Trials, and the Cochrane database. Experts were also contacted and reference lists searched. Studies were combined using the inverse variance fixed-effects model. Heterogeneity was assessed and a sensitivity analysis performed. Publication bias was also investigated. RESULTS Ten studies were identified that included 919 patients in which the Freedom (Sorin Biomedica Cardio, Via Crescentino, Italy), Freestyle (Medtronic, Minneapolis, MN), Prima Plus (Edwards Life Sciences, Irvine, CA) and the Toronto and Biocor (St Jude Medical, St. Paul, MN) valves were used. The mean aortic valve gradient was lower in the stentless groups, with a weighted mean difference (WMD) of -3.57 mm Hg (95% confidence interval [CI], -4.36 to -2.78; p < 0.01). The left ventricular mass index was significantly lower in the stentless groups at 6 months (WMD, -6.42; 95% CI, -11.63 to -1.21; p = 0.02), but this improvement disappeared after 12 months (WMD, 1.19; 95% CI, -4.15 to 6.53; p = 0.66). The weighted mean increase in cross-clamp time was 23 minutes, and the increase in bypass time was 29 minutes with a stentless valve. CONCLUSIONS This meta-analysis showed that stentless aortic valves provide an improved level of left ventricular mass regression at 6 months, reduced aortic gradients, and an improved effective orifice area index, at the expense of a 23-minute longer cross-clamp time and a 29-minute longer bypass time.
منابع مشابه
Haemodynamics and left ventricular mass regression: a comparison of the stentless, stented and mechanical aortic valve replacement.
OBJECTIVE Our objective was to compare the degree of change in hemodynamics and left ventricular mass (LVM) regression after aortic valve replacement (AVR) with stentless, stented and mechanical valves. METHODS Patients greater than 59 years of age had AVR for aortic stenosis with the stentless xenograft (Cryolife-O'Brien, CLOB), stented xenograft (Carpentier-Edwards, C-E) or mechanical valve...
متن کاملPerformance of stentless versus stented aortic valve bioprostheses in the elderly patient: a prospective randomized trial.
OBJECTIVES Although stentless aortic bioprostheses are believed to offer improved outcomes, benefits remain unsubstantiated. The aim of our study was to compare stentless with stented bioprostheses, with regard to postoperative changes in left ventricular mass and hemodynamic performance, in the elderly patient. METHODS Forty patients with aortic stenoses, over the age of 75 years, were rando...
متن کاملAre stentless valves superior to modern stented valves? A prospective randomized trial.
BACKGROUND It is presumed that stentless aortic bioprostheses are hemodynamically superior to stented bioprostheses. A prospective randomized controlled trial was undertaken to compare stentless versus modern stented valves. METHODS AND RESULTS Patients with severe aortic valve stenosis (n=161) undergoing aortic valve replacement (AVR) were randomized intraoperatively to receive either the C-...
متن کاملFull-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves
BACKGROUND Full-root aortic valve replacement with stentless xenografts has potentially superior hemodynamic performance compared to stented valves. However, a number of cardiac surgeons are reluctant to transform a classical stented aortic valve replacement into a technically more demanding full-root stentless aortic valve replacement. Here we describe our technique of full-root stentless aort...
متن کاملStentless aortic valves. Current aspects
The design of stentless valve prostheses is intended to achieve a more physiological flow pattern and superior hemodynamics in comparison to stented valves. First - generation stentless bioprosthesis were the Prima valve, the Freestyle valve and the Toronto stentless porcine valve. The second generation of stentless valves, as the Super stentless aortic porcine valve, need only one suture line....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of thoracic surgery
دوره 84 1 شماره
صفحات -
تاریخ انتشار 2007