Analysis of the March 1, 1999 Performance Evaluation HIV-1 p24 Antigen Testing Results
ثبت نشده
چکیده
This report is an analysis of results reported to the CDC by laboratories participating in the MPEP after they performed p24 antigen determinations on HIV-1 performance evaluation samples shipped to them March 1, 1999. Testing results were reported by 170 (91.9%) of the 185 laboratories that received sample panels. One laboratory returned results more than 2 weeks after the cut-off date and one laboratory reported results for the p24 antigen panel mailed in June, 1998, rather than the current panel. The results from these two laboratories are not included in this aggregate report.
منابع مشابه
Prospective evaluation of amplification-boosted ELISA for heat-denatured p24 antigen for diagnosis and monitoring of pediatric human immunodeficiency virus type 1 infection.
The performance in pediatric human immunodeficiency virus type 1 (HIV-1) infection of a signal-amplification boosted ELISA for HIV-1 p24 antigen in plasma after heat-mediated immune complex dissociation was prospectively compared with polymerase chain reaction-based procedures. Diagnostic sensitivity and specificity of the p24 antigen test were 100% and 99.2%, respectively. Quantification revea...
متن کاملU.S. Public Health Service guidelines for testing and counseling blood and plasma donors for human immunodeficiency virus type 1 antigen.
The Public Health Service (PHS) has recommended a multifaceted approach to blood safety in the United States that includes stringent donor selection practices and the use of screening tests. Blood donations in the United States have been screened for antibody to human immunodeficiency virus type 1 (HIV-1) since March 1985 and type 2 (HIV-2) since June 1992. An estimated one in 450,000 to one in...
متن کاملEvaluation of the Determine™ fourth generation HIV rapid assay.
Assays that detect p24 antigen reduce the diagnostic window period of HIV testing. Most point-of-care HIV assays have poor sensitivity to diagnose acute HIV infection as they only detect antibodies against HIV-1 and HIV-2 (HIV-1/2). This was a cross-sectional laboratory-based study that evaluated the performance of the Determine™ HIV-1/2 Ag/Ab Combo fourth generation rapid strip - currently the...
متن کاملNanoparticle-Based biobarcode amplification assay (BCA) for sensitive and early detection of human immunodeficiency type 1 capsid (p24) antigen.
Nanotechnology-based techniques are being widely evaluated in medical testing and could provide a new generation of diagnostic assays due to their high degrees of sensitivity, high specificity, multiplexing capabilities, and ability to operate without enzymes. In this article, we have modified a nanoparticle-based biobarcode amplification (BCA) assay for early and sensitive detection of HIV-1 c...
متن کاملGeneration of a Recombinant Gag Virus-Like-Particle Panel for the Evaluation of p24 Antigen Detection by Diagnostic HIV Tests
BACKGROUND Detection of HIV-1 p24 antigen permits early identification of primary HIV infection and timely intervention to limit further spread of the infection. Principally, HIV screening should equally detect all viral variants, but reagents for a standardised test evaluation are limited. Therefore, we aimed to create an inexhaustible panel of diverse HIV-1 p24 antigens. METHODS We generate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -