Speech quality evaluation of subcutaneously implanted microphone using in vivo experiment.
نویسندگان
چکیده
The microphone in a fully implantable hearing device (FIHD) is generally implanted under the skin covering the temporal bone. However, the implanted microphone can be affected by the skin, which causes both sound attenuation and distortion, particularly at high frequencies. As the degree of attenuation and distortion through the skin is severe, speech quality evaluation parameters are needed for the received signal when designing an implantable microphone. However, the performance of most implantable microphones is only assessed based on the sensitivity and frequency response. Thus, practical indicators based on human auditory characteristics are needed for an objective evaluation of the performance of implantable microphones. In this study, a subcutaneously implantable microphone was designed, and its frequency response investigated using an in vivo experiment. Plus, to evaluate the objective indicators, the speech quality of the signals measured by the implanted microphone was calculated using a MATLAB program, and the indicators compared before and after implantation.
منابع مشابه
شکلدهی وفقی و هوشمند پرتو در آرایههای میکروفونی Ad-hoc با استفاده از خوشهبندی و رتبهبندی میکروفونها
Considering the existence of a many speech degradation factors, speech enhancement has become an important topic in the field of speech processing. Beamforming is one of the well-known methods for improving the speech quality that is conventionally applied using regular (classical) microphone arrays. Due to the restrictions in the regular arrangement of microphones, in recent years there has be...
متن کاملSpeech Intelligibility of Cochlear-Implanted and Normal-Hearing Children
Introduction: Speech intelligibility, the ability to be understood verbally by listeners, is the gold standard for assessing the effectiveness of cochlear implantation. Thus, the goal of this study was to compare the speech intelligibility between normal-hearing and cochlear-implanted children using the Persian intelligibility test. Materials and Methods: Twenty-six cochlear-implanted childre...
متن کاملFabrication of a Novel MEMS Capacitive Microphone using Lateral Slotted Diaphragm
external amplifier was able to detect the sound waves from microphone on speaker and oscilloscope. The maximum amplitude of output speech signal of amplifier is 45 mV, and the maximum output of MEMS microphone is 1.125 µV.
متن کاملA new auditory based microphone array and objective evaluation using e-RASTI
Two are the goals of the work presented in this paper. The first one is the implementation of a new method of speech enhancement using microphone arrays. This method gets noise reduction of speech signal using the masking properties of the human auditory system. The second goal of the paper is to use RASTI index (RApid Speech Transmission Index) for objective evaluation of speech signal quality...
متن کاملAn evaluation of adaptive beamformer based on average speech spectrum for noisy speech recognition
Distant-talking speech recognition in noisy environments is indispensable for self-moving robots or tele-conference systems. However, background noise and room reverberations seriously degrade the sound-capture quality in real acoustic environments. A microphone array is an ideal candidate as an effective method for capturing distant-talking speech. AMNOR (Adaptive Microphone-array for NOise Re...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bio-medical materials and engineering
دوره 24 6 شماره
صفحات -
تاریخ انتشار 2014