Characterisation of breast implant surfaces and correlation with fibroblast adhesion.
نویسندگان
چکیده
INTRODUCTION Capsular contracture formation is a common complication following breast augmentation surgery. Breast implant shells have either a smooth or a textured surface. Smooth surfaces demonstrate a higher incidence of contracture formation. The 3-dimensional surface of textured implants is thought to disrupt contractile forces and reduce capsular contracture rates. AIM To investigate the interaction of fibroblasts with silicone breast implant surfaces through characterization of their unique features. METHOD Surfaces of smooth and textured breast implants were characterized using a confocal laser scanning microscope, a microtest 5 kN tensile testing device, and a contact angle goniometer. The kinetics of fibroblast interaction with these surfaces was further analysed. RESULTS The textured surfaces were rough, and nodular containing high peaks and deep crevasses with roughness (Sa) values in the range 8.88-18.83 μm and contact angles between 130° and 142°. The smooth implant surfaces were less rough, more regular and repetitive with 0.06-0.07 μm surface roughness, and contact angles between 110.9° and 111.8°. The textured surfaces displayed higher bending stiffness than the smooth surfaces (0.19 and 0.26 N mm). Significant (p<0.05) numbers of fibroblasts were attached to the textured surfaces compared to the smooth surfaces which had higher levels of cell adhesion with surface roughness above 8 μm and contact angles above 130°. CONCLUSIONS In summary, surfaces with arithmetical mean deviation of greater roughness and reduced hydrophilicity with high water contact angles enhanced cell adhesion. These features aid design of improved surfaces, which may help, in prevention of breast capsular formation.
منابع مشابه
Patterning of Novel Breast Implant Surfaces by Enhancing Silicone Biocompatibility, Using Biomimetic Topographies
INTRODUCTION AND AIMS Silicone biocompatibility is dictated by cell-surface interaction and its understanding is important in the field of implantation. The role of surface topography and its associated cellular morphology needs investigation to identify qualities that enhance silicone surface biocompatability. This study aims to create well-defined silicone topographies and examine how breast ...
متن کاملImplants modified with polymeric nanofibers coating containing the antibiotic vancomycin
Objective(S): Implant-related infections are disastrous complications in the clinic. One recent strategy to reduce the rate of infection is using the bioactive coating with an antibiotic. The purpose of these bioactive surfaces is to prevent bacterial adhesion to the implant and, consequently, the development of biofilm. In this study, vancomycin-loaded polymeric coating on imp...
متن کاملCurrent Implant Surface Technology: An Examination of Their Nanostructure and Their Influence on Fibroblast Alignment and Biocompatibility
UNLABELLED Systematic reviews indicate that breast implant texture confers a protective effect on capsular contracture. Fibroblasts are affected by micro- and nanotopographies. Few previous studies have investigated the inherent topographies of existing breast implants and the surfaces with which body tissue is exposed. AIMS To examine currently available breast implant surfaces at high resol...
متن کاملNumerical characterisation of biomedical titanium surface texture using novel feature parameters
In biomedicine, titanium materials with specific surface textures (for example, those produced using consecutive polishing, sandblasting and acid etching) are widely used to facilitate osseointegration of human/animal tissue with implant surface structures. The surface texture has a critical role on the material‟s functionality in terms of cellular adhesion and proliferation. However, conventio...
متن کاملIn vitro Biocompatibility of New Silver(I) Coordination Compound Coated-Surfaces for Dental Implant Applications
Biofilm formation on implant materials causes a common problem: resistance to aggressive pharmacological agents as well as host defenses. Therefore, to reduce bacterial adhesion to implant surfaces we propose to use silver(I) coordination networks as it is known that silver is the most powerful antimicrobial inorganic agent. As a model surface, self-assembled monolayers (SAMs) on gold Au(111) w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the mechanical behavior of biomedical materials
دوره 21 شماره
صفحات -
تاریخ انتشار 2013