New Validated Signal-averaging-based Electrocardiography Method to Determine His-ventricle Interval.
نویسندگان
چکیده
BACKGROUND/AIM The signal-averaging (SA) technique is used to record high-resolution electrocardiograms (HRECGs) showing cardiac micropotentials. We aimed to develop a non-invasive signal-averaging-based portable bedside device to determine His-ventricle interval. PATIENTS AND METHODS After amplifying the HRECG recordings, signal duration and voltage can be measured up to four decimal precision. To validate our system, comparison of the invasively and non-invasively determined HV intervals has been performed in 20 patients. RESULTS Our workgroup has developed a system capable of displaying and measuring cardiac micropotentials on storable ECG. Neither related paired-sample T-test (p=0.263) nor Wilcoxon's non-parametric signed ranks test (p=0.245) showed significant deviations of the HV intervals. Furthermore, related paired-sample T-test showed strong correlation (corr=0.910, p<0.001) between HV intervals determined by electrophysiology (EP) and non-invasive measurements. CONCLUSION Our research group managed to assemble and validate an easy to use device capable of determining HV intervals even under ambulatory conditions.
منابع مشابه
Enhancement of Noise Performance in Digital Receivers by Over Sampling the Received Signal
In wireless channel the noise has a zero mean. This channel property can be used in the enhancement of the noise performance in the digital receivers by oversampling the received signal and calculating the decision variable based on the time average of more than one sample of the received signal. The averaging process will reduce the effect of the noise in the decision variable that will approa...
متن کاملNoninvasive Recording of His-Purkinje Activity in Man by QRS-Triggered Signal Averaging
Mobile instrumentation and a clinically applicable method have been developed for external His bundle recording. High gain signal amplification (105) filtering (30-300 Hz) and averaging (128 or 256 consecutive cycles) are used. Acquisition of signals arising in the P-R interval is triggered by the patient's QRS signal at the end of that interval. The precordial bipolar electrocardiogram is digi...
متن کامل[Management of atrioventricular conduction abnormalities in myotonic dystrophy].
Sudden death is a serious problem in patients with myotonic dystrophy. Atrioventricular blocks (AVBs) and tachyarrhythmias are regarded as a cause of the cardiac sudden death. The increase of QRS width and the deviation of electrical axis are rather important because the main lesion of AVB is located in His-Purkinje system, while the prolongation of PR interval attracts our attention for AVB. T...
متن کاملA novel approach for the averaging of magnetocardiographically recorded heart beats.
Performing signal averaging in an efficient and correct way is indispensable since it is a prerequisite for a broad variety of magnetocardiographic (MCG) analysis methods. One of the most common procedures for performing the signal averaging to increase the signal-to-noise ratio (SNR) in magnetocardiography, as well as in electrocardiography (ECG), is done by means of spatial or temporal techni...
متن کاملSignal detection Using Rational Function Curve Fitting
In this manuscript, we proposed a new scheme in communication signal detection which is respect to the curve shape of received signal and based on the extraction of curve fitting (CF) features. This feature extraction technique is proposed for signal data classification in receiver. The proposed scheme is based on curve fitting and approximation of rational fraction coefficients. For each symbo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- In vivo
دوره 30 6 شماره
صفحات -
تاریخ انتشار 2016