Microbial prevalence in domestic humidifiers.

نویسندگان

  • H A Burge
  • W R Solomon
  • J R Boise
چکیده

The prevalence of viable thermophilic bacteria and actinomycetes and mesophilic fungi was examined in 145 samples from 110 domestic humidifiers. A total of 72 and 43% of furnace and console humidifier samples, respectively, contained viable thermophilic bacteria, whereas 60 and 72% of these samples produced mesophilic fungal growth. Thermophilic actinomycetes were recovered from seven humidifier samples. Efforts to detect thermophilic actinomycete antigens in 15 humidifier fluid samples were not successful. Antifoulants added to humidifier fluid reservoirs had no apparent effect on microbial frequency. Airborne microbial recoveries did not reflect patterns of humidifier contamination with respect to either kinds or numbers of microorganisms in 20 homes in which volumetric air samples were obtained during humidifier operation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessing Inhalation Exposures Associated with Contamination Events in Water Distribution Systems

When a water distribution system (WDS) is contaminated, short-term inhalation exposures to airborne contaminants could occur as the result of domestic water use. The most important domestic sources of such exposures are likely to be showering and the use of aerosol-producing humidifiers, i.e., ultrasonic and impeller (cool-mist) units. A framework is presented for assessing the potential effect...

متن کامل

Humidifiers for oxygen therapy: what risk for reusable and disposable devices?

INTRODUCTION Nosocomial pneumonia accounts for the vast majority of healthcare-associated infections (HAI). Although numerous medical devices have been discussed as potential vehicles for microorganisms, very little is known about the role played by oxygen humidifiers as potential sources of nosocomial pathogens. The purpose of this research was to evaluate the safety of the reuse of humidifier...

متن کامل

Humidifiers: the use of biocides and lung disease.

Over the last two decades several publications have reported outbreaks of interstitial lung disease caused by inhalational exposure to a chemical, usually at work, but occasionally in a domestic situation. These outbreaks frequently follow a change in formulation, which may be minor, of a chemical already being used in the workplace, or a change in process leading to its aerosolisation. In 2006...

متن کامل

Continuous Positive Airway Pressure: Is it a route for infection in those with Obstructive Sleep Apnoea?

INTRODUCTION Continuous positive airway pressure (CPAP) is the standard treatment for obstructive sleep apnoea (OSA), with limited data about the prevalence of respiratory infections and microbial colonization in these patients. OBJECTIVES The aim of this study was to determine if CPAP use is associated with respiratory infections and to identify the organisms that colonize or infect these pa...

متن کامل

بررسی فراوانی آلودگی انسان، دام و طیور به کریپتوسپوریدیوم در شهرستان همدان و حومه در طی سالهای 1390- 1385

Introduction & Objective: Cryptosporidium is one of the important pathogenic agents of gastero intestinal tract of mammals, especially human and domestic animals. This parasite is one of the principal causative agents of mortality in young animals. Considering the zoonotic importance of the parasite, infected animals can be very dangerous to the public health. This study was performed to dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 39 4  شماره 

صفحات  -

تاریخ انتشار 1980