Dynamic Grid Support in Low Voltage Grids – Fault Ride-Through and Reactive Power/Voltage Support during Grid Disturbances

نویسندگان

  • Gustav Lammert
  • Tobias Heß
  • Maximilian Schmidt
  • Peter Schegner
  • Martin Braun
چکیده

Faults in medium and high voltage grids lead to voltage sags in the low voltage level. Due to the voltage dip, distributed generators disconnect from the low voltage grid. Depending on the amount of disconnected generation, system stability could be compromised. With a dynamic grid support, distributed generators remain connected to the grid during faults, also called fault ride-through. Moreover, the feed in of reactive power supports the voltage during the fault. According to the present state of the art, no requirements exist for a dynamic grid support in low voltage grids. However, with a high penetration of distributed generation these requirements might change in the future. This paper investigates the dynamic grid support in low voltage grids. The impact of a dynamic grid support on a distribution grid is studied with IEEE/CIGRE benchmark models for low and medium voltage grids. Models of inverters, directly-coupled synchronous and induction generators are implemented. Furthermore, a present and a future protection system with fault ridethrough capability are added to the grid models. The inverters are equipped with a reactive current controller to give a voltage support during faults. To determine the effect of a dynamic grid support, faults in high and medium voltage grids with and without dynamic grid support are simulated and evaluated. The results have shown that the effect of the voltage boost through dynamic grid support in order to recover the voltage is marginal. However, with a high penetration level of distributed generators the voltage boost increases and the impact of faults can be further limited. This investigation has demonstrated the potential of dynamic grid support in low voltage grids to avoid the loss of a large amount of power and to improve the voltage recovery. Keywords—Dynamic Grid Support, Fault Ride-Through, Low Voltage Ride-Through, Reactive Power/Voltage Support, Low Voltage Grid

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Voltage Ride-Through Capability Improvement of Doubly Fed Induction Generator using DVR and SMES

Abstract: With the growth of communities and the increasing need for electricity, and because of the many benefits of renewable energy sources, the wind turbine has become a completely commercial and inevitable process, with increasing penetration into the electricity grid. Distribution networks, on the other hand, are subject to fault that cause power fluctuations and outflow of wind units. In...

متن کامل

Efficient low-voltage ride-through nonlinear backstepping control strategy for PMSG-based wind turbine during the grid faults

This paper presents a new nonlinear backstepping controller for a direct-driven permanent magnet synchronous generator-based wind turbine, which is connected to the power system via back-to-back converters. The proposed controller deals with maximum power point tracking (MPPT) in normal condition and enhances the low-voltage ride-through (LVRT) capability in fault conditions. In this method, to...

متن کامل

Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

متن کامل

Design of A Single-Phase Transformerless Grid-Connected PV Inverter ‎Considering Reduced Leakage Current and LVRT Grid Codes

A new single-phase transformerless grid-connected PV inverter is presented in this paper. Investigations in transformerless grid-connected PV inverters indicate the existence of the leakage current is directly related to the variable common-mode voltage (CMV), which is presented in detail. On the other hand, in recent years it has become mandatory for the transformerless grid-connected PV inver...

متن کامل

Control System Design and Fault-Ride-through Performance Analysis of Grid-Connected Microturbine Generation System

In recent years, microturbines as one the distributed generation sources have widly used. This paper investigates the control structure of the microturbine and analyzes its performance in grid-connected mode. In this way, first, the mechanical model of the microturbine is presented. Then, the electrical structure of the microturbine, consisting  of permanent magnet synchronous generator (PMSG) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014