Comparison of the quality of chest compressions on a dressed versus an undressed manikin: A controlled, randomised, cross-over simulation study
نویسندگان
چکیده
BACKGROUND Undressing the chest of a cardiac arrest victim may delay the initiation of chest compressions. Furthermore, expecting laypeople to undress the chest may increase bystander reluctance to perform cardiopulmonary resuscitation (CPR). Both of these factors might conceivably decrease survival following cardiac arrest. Therefore, the aim of this study was to examine if the presence or absence of clothes affected the quality of chest compressions during CPR on a simulator manikin. METHODS Thirty laypeople and 18 firefighters were randomised to start CPR on the thorax of a manikin that was either clothed (three layers) or not. Data were obtained via recordings from the manikin and audio- and video-recordings. Measurements were: maximum compression depth; compression rate; percentage of compressions with correct hand positioning; percentage of compressions with complete release (< or = 10 mm), and percentage of compressions of the correct depth (range 40-50 mm). Laypeople were given a four-hour European Resuscitation Council standardised course in basic life support and tested immediately after. Firefighters were tested without additional training. Mock cardiac arrest scenarios consisted of three minutes of CPR separated by 15 minutes of rest. RESULTS No significant differences were found between CPR performed on an undressed manikin compared to a dressed manikin, for laypeople or firefighters. However, undressing the manikin was associated with a mean delay in the initiation of chest compressions by laypeople of 23 seconds (N = 15, 95% CI: 19;27). CONCLUSIONS In this simulator manikin study, there was no benefit gained in terms of how well CPR was performed by undressing the thorax. Furthermore, undressing the thorax delayed initiation of CPR by laypeople, which might be clinically detrimental for survival.
منابع مشابه
The impact of chest compression rates on quality of chest compressions - a manikin study.
PURPOSE Chest compressions are often performed at a variable rate during cardiopulmonary resuscitation (CPR). The effect of compression rate on other chest compression quality variables (compression depth, duty-cycle, leaning, performance decay over time) is unknown. This randomised controlled cross-over manikin study examined the effect of different compression rates on the other chest compres...
متن کاملEfficacy of acute care health care providers in cardiopulmonary resuscitation compressions in normal and obese adult simulation manikins.
Annually, over 350,000 persons require cardiopulmonary resuscitation (CPR), either in or outside of the hospital. With obesity a rising health issue in the United States, concerns exist regarding the efficacy of quality compressions for CPR in obese patients. The aims of this study were to determine if the compressions for three adult simulation manikins (normal, obese, and morbidly obese) met ...
متن کاملComparison of direct intubation and Supraglottic Airway Laryngopharyngeal Tube (S.A.L.T.) for endotracheal intubation during cardiopulmonary resuscitation. Randomized manikin study.
BACKGROUND Airway control is a potentially lifesaving procedure, but intubation by direct laryngoscopy may be difficult. The aim of this study was to assess the success rate of tracheal intubation using the Macintosh laryngoscope and Supraglottic Airway Laryngopharyngeal Tube (S.A.L.T) device. METHODS This is a randomised cross-over study involving 120 paramedics utilising the Macintosh laryn...
متن کاملRandomised crossover trial of rate feedback and force during chest compressions for paediatric cardiopulmonary resuscitation
OBJECTIVE To determine the effect of visual feedback on rate of chest compressions, secondarily relating the forces used. DESIGN Randomised crossover trial. SETTING Tertiary teaching hospital. SUBJECTS Fifty trained hospital staff. INTERVENTIONS A thin sensor-mat placed over the manikin's chest measured rate and force. Rescuers applied compressions to the same paediatric manikin for two...
متن کاملComparison of Pentax-AWS Airwayscope and Glidescope for Infant Tracheal Intubation by Anesthesiologists during Cardiopulmonary Arrest Simulation: A Randomized Crossover Trial
BACKGROUND Recent guidelines for infant cardiopulmonary resuscitation emphasize that all rescuers should minimize interruption of chest compressions, even for endotracheal intubation. We compared the utility of the Pentax-AWS Airwayscope (AWS) with the Glidescope (GS) during chest compressions on an infant manikin. METHODS Twenty-four anesthesiologists with more than two years of experience p...
متن کامل