Priority-driven plan optimization in locally advanced lung patients based on perfusion SPECT imaging
نویسندگان
چکیده
PURPOSE Limits on mean lung dose (MLD) allow for individualization of radiation doses at safe levels for patients with lung tumors. However, MLD does not account for individual differences in the extent or spatial distribution of pulmonary dysfunction among patients, which leads to toxicity variability at the same MLD. We investigated dose rearrangement to minimize the radiation dose to the functional lung as assessed by perfusion single photon emission computed tomography (SPECT) and maximize the target coverage to maintain conventional normal tissue limits. METHODS AND MATERIALS Retrospective plans were optimized for 15 patients with locally advanced non-small cell lung cancer who were enrolled in a prospective imaging trial. A staged, priority-based optimization system was used. The baseline priorities were to meet physical MLD and other dose constraints for organs at risk, and to maximize the target generalized equivalent uniform dose (gEUD). To determine the benefit of dose rearrangement with perfusion SPECT, plans were reoptimized to minimize the generalized equivalent uniform functional dose (gEUfD) to the lung as the subsequent priority. RESULTS When only physical MLD is minimized, lung gEUfD was 12.6 ± 4.9 Gy (6.3-21.7 Gy). When the dose is rearranged to minimize gEUfD directly in the optimization objective function, 10 of 15 cases showed a decrease in lung gEUfD of >20% (lung gEUfD mean 9.9 ± 4.3 Gy, range 2.1-16.2 Gy) while maintaining equivalent planning target volume coverage. Although all dose-limiting constraints remained unviolated, the dose rearrangement resulted in slight gEUD increases to the cord (5.4 ± 3.9 Gy), esophagus (3.0 ± 3.7 Gy), and heart (2.3 ± 2.6 Gy). CONCLUSIONS Priority-driven optimization in conjunction with perfusion SPECT permits image guided spatial dose redistribution within the lung and allows for a reduced dose to the functional lung without compromising target coverage or exceeding conventional limits for organs at risk.
منابع مشابه
Covid-19 manifestation on Tl-201 myocardial perfusion SPECT/CT
A 67 years old woman was referred to nuclear medicine center for myocardial perfusion imaging (MPI) for assessment of ischemic heart dieses (IHD).She had a history of atypical chest pain and dyspnea since about 10 days before admission. The MPI SPECT/CT was performed by stress/redistribution Tl-201 protocol. MPI was interpreted as relatively good coronary flow with no appreciable stress induced...
متن کاملSpurious lung perfusion ventilation defect on planar ventilation-perfusion scan detected by SPECT imaging
Pulmonary embolism (PE) is a preventable cause of morbidity and mortality which needs prompt recognition. Ventilation-perfusion (V/Q) scan is a well-established diagnostic test for evaluation of suspected PE. We report a 32-year-old woman with history of rheumatologic disease and acute dyspnea, who was referred for V/Q scintigraphy. The planar images revealed multiple mismatched defects through...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملComparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group
Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...
متن کاملThe influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
Introduction: Integration of single photon emission computed tomography (SPECT) and computed tomography (CT) scanners into SPECT/CT hybrid systems permit detection of coronary artery disease in myocardial perfusion imaging (MPI). Misregistration between CT and emission data can produce some errors in uptake value of SPECT images. The aim of this study was evaluate the influence...
متن کامل