Normal Values of Standard Full Field Electroretinography in an Iranian Population

نویسندگان

  • Mohammad-Mehdi Parvaresh
  • Leila Ghiasian
  • Khalil Ghasemi Falavarjani
  • Mostafa Soltan Sanjari
  • Nadia Sadighi
چکیده

PURPOSE To determine normal values of standard full-field electroretinography (ERG) and to evaluate their variations with age in an Iranian population. METHODS Through convenient sampling, 170 normal subjects 1-80 years of age were selected from residents of Tehran. ERG amplitudes and implicit time values were measured according to recommendations by the International Society for Clinical Electrophysiology of Vision. Evaluations consisted of light-adapted ERG including single-white flash and 30-Hz flicker response; and dark-adapted ERG including rod, maximal dark-adapted and cone responses. RESULTS No significant difference in ERG values was observed between men and women, or between right and left eyes. ERG amplitudes were lower (P=0.04) and implicit time values were greater (P=0.03) in subjects 70-80 years of age as compared to younger individuals. CONCLUSION ERG parameters are significantly diminished with age. Our results may serve as a reference against which standard ERG responses can be compared.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal Values of Standard Full Field Electroretinography in Healthy Subjects in Northern Iran

Background: Electroretinography (ERG) is known as a diagnostic test for evaluating the performance of different layers of the retina. Its normal values maybe different in different populations. Objectives: Determining the normal values of ERG parameters in patients presenting to an ophthalmologic center in Guilan in northern Iran. Materials and Methods: Fifty-five people presenting to a teach...

متن کامل

Evaluation of Normal Exophthalmometric Values in Iranian Population: A Systematic Review and Meta-Analysis

Normal level of eye protrusion is different in various populations and many factors such as age, sex, race, refractive error, and anthropometric characteristics affect it. There are limited studies in Iran about the normal amount of eye protrusion in healthy population and normal exophthalmometric values. In this meta-analysis, taking into account the results of the 4 studies, we decided to obt...

متن کامل

Standardized Full-Field Electroretinography in the Green Monkey (Chlorocebus sabaeus)

Full-field electroretinography is an objective measure of retinal function, serving as an important diagnostic clinical tool in ophthalmology for evaluating the integrity of the retina. Given the similarity between the anatomy and physiology of the human and Green Monkey eyes, this species has increasingly become a favorable non-human primate model for assessing ocular defects in humans. To tes...

متن کامل

Retina in rheumatic diseases: standard full field and multifocal electroretinography in hydroxychloroquine retinal dysfunction.

BACKGROUND The purpose of this study was to evaluate and compare full-field electroretinography (ERG) and multifocal electroretinography (mfERG) results in detecting retinal dysfunction in a large number of asymptomatic patients treated with hydroxychloroquine (Hy). METHODS Fifty eyes in 50 patients with rheumatic diseases who had been using Hy for a period of time ranging from 30 months to 1...

متن کامل

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2009