Guidelines and recommended terms for expression of stable-isotope-ratio and gas-ratio measurement results.

نویسنده

  • Tyler B Coplen
چکیده

To minimize confusion in the expression of measurement results of stable isotope and gas-ratio measurements, recommendations based on publications of the Commission on Isotopic Abundances and Atomic Weights of the International Union of Pure and Applied Chemistry (IUPAC) are presented. Whenever feasible, entries are consistent with the Système International d'Unités, the SI (known in English as the International System of Units), and the third edition of the International Vocabulary of Basic and General Terms in Metrology (VIM, 3rd edition). The recommendations presented herein are approved by the Commission on Isotopic Abundances and Atomic Weights and are designed to clarify expression of quantities related to measurement of isotope and gas ratios to ensure that quantity equations instead of numerical value equations are used for quantity definitions. Examples of column headings consistent with quantity calculus (also called the algebra of quantities) and examples of various deprecated usages connected with the terms recommended are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Labeling of Human Serum Albumin with Stable Isotope of Bromine; an in Vitro Study

Background: Possibility to trace-label albumin with isotopes results in information concerning its synthesis, breakdown, and distribution in the intra and extra cellular spaces. The iodination of albumin is a widespread procedure used in scientific studies. Bromine not only is more reactive and less expensive than iodine, but bonds more easily with many elements. Therefore, it could be a suitab...

متن کامل

Simple, Real-Time Measurement of Stable Isotope Ratios in H2O and CO2

Picarro WS-CRDS-based analyzers are the first instruments to combine simple, turnkey operation with sensitivity and precision better than or equal to the IRMS (isotope ratio mass spectrometer) systems traditionally used in stable isotope labs. This opens the door for widespread exploitation of stable isotope studies in fields such as carbon/water cycle research, GHG (greenhouse gas) monitoring,...

متن کامل

Nicotine, acetanilide and urea multi-level 2H-, 13C- and 15N-abundance reference materials for continuous-flow isotope ratio mass spectrometry.

Accurate determinations of stable isotope ratios require a calibration using at least two reference materials with different isotopic compositions to anchor the isotopic scale and compensate for differences in machine slope. Ideally, the delta values of these reference materials should bracket the isotopic range of samples with unknown delta values. While the practice of analyzing two isotopica...

متن کامل

High precision isotope ratio monitoring techniques in mass spectrometry.

Isotope ratio monitoring following on-line combustion is a new method in gas chromatography/mass spectrometry (GC/MS) that allows the ratios of abundances of stable isotopes of elements such as carbon and nitrogen to be determined for individual compounds introduced via a gas chromatograph. It is the first combustion method that allows direct measurement of isotope ratios of individual molecula...

متن کامل

Stable Isotope Application in Animal Nutrition Science

The application of stable isotope analysis (SIA) has become a standard scientific approach in Agricultural and Ecological researches and, more in general, in several disciplines such as biology, botany, zoology, organic chemistry, climatology, and nutrition. The main objectives of this paper are (1) to provide a simple definition of stable isotopes and (2) to illustrate analytical measurement m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Rapid communications in mass spectrometry : RCM

دوره 25 17  شماره 

صفحات  -

تاریخ انتشار 2011