A 22-plex chemiluminescent microarray for pneumococcal antibodies.

نویسندگان

  • Jerry W Pickering
  • Justin D Hoopes
  • Matthew C Groll
  • Heidi K Romero
  • Dave Wall
  • Howard Sant
  • Mark E Astill
  • Harry R Hill
چکیده

We developed a chemiluminescent multiplexed microarray that simultaneously determines IgG antibody concentrations to 22 pneumococcal polysaccharide (PnPs) serotypes (1, 2, 3, 4, 5, 6B, 7F, 8, 9N, 9V, 10A, 11A, 12F, 14, 15B, 17F, 18C, 19A, 19F, 20, 23F, and 33F). We compared the microarray with an enzyme-linked immunosorbent assay (ELISA) for 9 of the 22 serotypes (1, 4, 5, 6B, 9V, 14, 18C, 19F, and 23F). Correlation coefficients (r2) for the comparison of the microarray with ELISA ranged from 0.91 to 0.97 for the 9 serotypes. The microarray detected more than 4-fold increases in antibody concentrations in serum samples from before and 1 month after administration of pneumococcal vaccine for all 22 serotypes tested. The mean interassay and intra-assay coefficients of variation for 12 serum samples for the 22 serotypes were 7.6% and 6.0%, respectively. Inhibition-of-binding studies showed more than 90% inhibition by homologous serotypes and, with few exceptions, less than 25% inhibition by heterologous serotypes. The microarray multiplexing technology is an attractive alternative to ELISA for antibody responses to 23-valent PnPs vaccines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Chemiluminescent Protein Microarray Method for Determining the Seroglycoid Fucosylation Index

The Lens culinaris agglutinin-reactive fraction of AFP (AFP-L3) is widely used to screen for hepatocellular carcinoma (HCC) in Japan and China. We developed a chemiluminescent protein microarray for determining the AFP-L3/AFP index (the ratio of AFP-L3 to total AFP, AFP-L3%) by fixing AFP-specific antibodies and Lens culinaris lectin on aldehyde-coated glass slides. Serum samples were tested fo...

متن کامل

Development and validation of a fourfold multiplexed opsonization assay (MOPA4) for pneumococcal antibodies.

Opsonophagocytic killing assays (OPAs) are essential for developing and improving pneumococcal vaccines. There is a need for a high-throughput, reliable, standardized, and fully characterized OPA for pneumococcal antibodies. To meet the need, we have developed and characterized a fourfold multiplexed OPA (MOPA4) against 13 serotypes (1, 3, 4, 5, 6A, 6B, 7F, 9V, 14, 18C, 19A, 19F, and 23F) of pn...

متن کامل

Multiplexed Electrochemical Detection of Yersinia Pestis and Staphylococcal Enterotoxin B using an Antibody Microarray

The CombiMatrix antibody microarray is a versatile, sensitive detection platform based on the generation and transduction of electrochemical signals following antigen binding to surface antibodies. The sensor chip described herein is comprised of microelectrodes coupled to an adjacent bio-friendly matrix coated with antibodies to the biological pathogens Yersinia pestis and Bacillus anthracis, ...

متن کامل

Development of polyclonal antibodies for detection of protein modification by 1,2-naphthoquinone.

Naphthoquinones have been reported to be toxic to liver cells in vitro. Protein modification is associated with naphthoquinone-induced cytotoxicity. In addition, 1,2-naphthoquinone was found to bind covalently to cysteine residues of proteins of lung Clara cells incubated with naphthalene. To further identify the target proteins of the naphthoquinone, we raised polyclonal antibodies by immunizi...

متن کامل

Diagnosis of pneumococcal pneumonia by enzyme-linked immunosorbent assay of antibodies to pneumococcal hemolysin (pneumolysin).

An enzyme-linked immunosorbent assay (ELISA) with a highly purified pneumolysin as the antigen was evaluated for serological diagnosis of pneumococcal pneumonia. One hundred four healthy controls were tested, and the specificity of the test was set to 95%. In samples from patients with bacteremic pneumococcal pneumonia, 82% (18 of 22) were positive, i.e., at least one serum sample had a titer a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 128 1  شماره 

صفحات  -

تاریخ انتشار 2007