The effect of pitch in multislice spiral/helical CT.

نویسندگان

  • G Wang
  • M W Vannier
چکیده

The purpose of this study is to understand the effect of pitch on raw data interpolation in multislice spiral/helical computed tomography (CT) and provide guidelines for scanner design and protocol optimization. Multislice spiral CT is mainly characterized by the three parameters: the number of detector arrays, the detector collimation, and the table increment per x-ray source rotation. The pitch in multislice spiral CT is defined as the ratio of the table increment over the detector collimation in this study. In parallel to the current framework for studying longitudinal image resolution, the central fan-beam rays of direct and opposite directions are considered, assuming a narrow cone-beam angle. Generally speaking, sampling in the Radon domain by the direct and opposite central rays is nonuniform along the longitudinal axis. Using a recently developed methodology for quantifying the sensitivity of signal reconstruction from nonuniformly sampled finite points, the effect of pitch on raw data interpolation is analyzed in multislice spiral CT. Unlike single-slice spiral CT, in which image quality decreases monotonically as the pitch increases, the sensitivity of raw data interpolation in multislice spiral CT increases in an alternating way as the pitch increases, suggesting that image quality does not decrease monotonically in this case. The most favorable pitch can be found from the sensitivity-pitch plot for any given set of multislice spiral CT parameters. An example for four-slice spiral CT is provided. The study on the effect of pitch using the sensitivity analysis approach reveals the fundamental characteristics of raw data interpolation in multislice spiral CT, and gives insights into interaction between pitch and image quality. These results may be valuable for design of multislice spiral CT scanners and imaging protocol optimization in clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Principles of CT: multislice CT.

This article describes the principles and evolution of multislice CT (MSCT), including conceptual differences associated with slice definition, cone beam effects, helical pitch, and helical scan technique. MSCT radiation dosimetry is described, and dose issues associated with MSCT-and with CT in general-as well as techniques for reducing patient radiation dose are discussed. Factors associated ...

متن کامل

Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose

Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...

متن کامل

Guest Editorial - Multirow Detector and Cone-Beam Spiral/Helical CT

S PIRAL/HELICAL multirow detector computed tomog-raphy (MDCT), also referred to as multislice spiral CT (MSCT), has attracted a major interest since its recent introduction [18], [33]. Compared with single-row-detector systems, MDCT scanners allow faster data collection and thinner slices that support more demanding clinical applications and present new research opportunities. This special issu...

متن کامل

A knowledge-based cone-beam x-ray CT algorithm for dynamic volumetric cardiac imaging.

With the introduction of spiral/helical multislice CT, medical x-ray CT began a transition into cone-beam geometry. The higher speed, thinner slice, and wider coverage with multislice/cone-beam CT indicate a great potential for dynamic volumetric imaging, with cardiac CT studies being the primary example. Existing ECG-gated cardiac CT algorithms have achieved encouraging results, but they do no...

متن کامل

Liver metastases: optimizing detection with multislice CT (MSCT)

Conventional, single-slice helical computed tomography (CT) allows for scanning the majority of the liver during the critical portal venous phase. This is often referred to as the ‘optimal temporal window’. In general, it occurs following a 70-s scan delay and is coincidental with the maximal delivery of contrast via the portal vein that provides 80% of the hepatic blood supply. This yields max...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 26 12  شماره 

صفحات  -

تاریخ انتشار 1999