Accuracy of frequency domain analysis scenarios for the determination of complex dielectric permittivity

نویسندگان

  • J. A. Huisman
  • W. Bouten
  • J. A. Vrugt
  • P. A. Ferré
چکیده

[1] Frequency domain analysis of time domain reflectometry waveforms has been shown to be useful for more accurate water content determination, water content determination in saline soils, and determination of such difficult to measure soil properties as specific surface area and soil solution conductivity. Earlier frequency domain analysis approaches to determine frequency-dependent dielectric properties of soils have used a variety of methods. In this paper, these methods for the determination of dielectric permittivity were compared using the Shuffled Complex Evolution Metropolis algorithm (SCEM-UA). SCEM-UA is a global optimization method that allows the simultaneous determination of optimal Debye parameters, which describe the dielectric permittivity as a function of frequency, and their confidence intervals. The analysis of numerically generated measurements with added instrumental noise showed that analysis of network analyzer measurements in the frequency domain potentially has the highest accuracy for determination of dielectric permittivity. Furthermore, the analysis of time domain reflectometry waveforms in the time domain was found to be more accurate than analysis of these waveforms in the frequency domain. Analysis of real network analyzer measurements in the time and frequency domain showed that both analysis scenarios allowed reasonably accurate estimates of the Debye parameters with the SCEM-UA algorithm, even when the true value of a parameter falls beyond the limits of the frequency bandwidth. However, frequency domain analysis of ethanol measurements showed that results were susceptible to model errors caused by nonideal probe behavior. These errors were larger for three-wire probes than for seven-wire probes. This study shows that the accuracy of the dielectric permittivity determination can be improved by reducing the model error. This can be achieved by the use of more accurate models, such as multiscatter functions, and by using more advanced probes, such as coaxial cells. The results also imply that future research on dielectric properties of soils should focus more on the use of network analyzers instead of cable testers, since model errors are more obvious in the frequency domain. The SCEM-UA algorithm proved to be a valuable tool in frequency domain analysis because reported problems with parameter identification and initialization of the optimization are circumvented with this global optimization algorithm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

معرفی و شبیه سازی روش جدید اندازه گیری ضریب تلفات عایقی و پرمتیویته نسبی

For evaluating quality of electrical insulation, it is necessary to measure the property of insulators. Dielectric constant and loss tangent (tans) are two important parameters for determining the property of insulator. The measurement of above parameters is normally based on the time- domain and frequency-domain, which is costly and time consuming. In this study a multiple-frequency binary se...

متن کامل

Determination of Resonance Frequency of Dominant and Higher Order Modes in Thin and Thick Circular Microstrip Patch Antennas with Superstrate by MWM (RESEARCH NOTE)

An accurate model named as the Modified Wolff Model (MWM) is presented as an efficient CAD tool for determination of resonant frequency of the dominant and higher order modes under the multi-layer condition in thin and thick circular microstrip patch antennas. The effects of dielectric cover on the resonant frequency obtained from MWM have been compared against the result of theoretical method ...

متن کامل

Determination of Complex Permittivity with Neural Networks and Fdtd Modeling

A simple novel cavity-independent method of determination of dielectric properties of arbitrarily shaped materials is presented. Complex permittivity is reconstructed using a neural networking procedure matching the measured and FDTD-modeled frequency characteristics of the reflection coefficient. High accuracy and practical suitability are demonstrated through numerical testing and determinati...

متن کامل

Determination of Soil Pore Water Salinity Using an FDR Sensor Working at Various Frequencies up to 500 MHz

This paper presents the application of a frequency-domain reflectometry (FDR) sensor designed for soil salinity assessment of sandy mineral soils in a wide range of soil moisture and bulk electrical conductivity, through the determination of soil complex dielectric permittivity spectra in the frequency range 10-500 MHz. The real part of dielectric permittivity was assessed from the 380-440 MHz,...

متن کامل

Estimation of Moisture in Transformer Insulation Using Dielectric Frequency Response Analysis by Heuristic Algorithms

Transformers are one of the most valuable assets of power systems. Maintenance and condition assessment of transformers has become one of the concerns of researchers due to huge number of transformers has been approached to the end of their lifetimes. Transformer’s lifetime depends on the life of its insulation and the insulation’s life is strongly influenced by its moisture attraction as well....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004