Influence of inter-root septum width on mini-implant stability
نویسندگان
چکیده
Objective: The purpose of this study was to evaluate the influence of the inter-radicular septum width in the insertion site of self-drilling mini-implants on the stability degree of these anchorage devices. Methods: The sample consisted of 40 mini-implants inserted in the inter-radicular septum between maxillary second premolars and first molars in 21 patients to provide skeletal anchorage for anterior retraction. The post-surgical radiographs were used to measure the septum width in the insertion site (ISW). In this regard, the mini-implants were divided in two groups: group 1 (critical areas, ISW≤3 mm) and group 2 (non-critical areas, ISW>3 mm). The degree of mobility (DM) was monthly quantified to determine mini-implant stability, and the success rate of these devices was calculated. This study also evaluated the sensitivity degree during miniscrew load, amount of plaque around the miniscrew, insertion height, and total evaluation period. Results: The results showed no significant difference in mobility degree and success rate between groups 1 and 2. The total success rate found was 90% and no variable was associated with the miniscrew failure. Nevertheless, the results showed that greater patient sensitivity degree was associated to the mini-implant mobility and the failure of these anchorage devices happened in a short time after their insertion. Conclusion: Septum width in the insertion site did not influence the self-drilling miniimplant stability evaluated in this study. Abstract
منابع مشابه
Anatomically guided implant site preparation technique at molar sites.
Immediate postextraction implant placement in the areas of multiradicular teeth is a difficult procedure in view of having to place the implant in an ideal position without jeopardizing its initial stability. The surgeon often faces the problem of directing the initial osteotomy in the medial portion of the alveolus with the difficulty of engaging the inter-radicular septum of the extraction so...
متن کاملEvaluation of the implantation position of mini-screws for orthodontic treatment in the maxillary molar area by a micro CT.
The interalveolar septum between the upper first molar and the second premolar of the separated human maxillary bone was three-dimensionally observed by micro CT to evaluate the appropriate mini-screw type implant placement position by considering the relationship between the tooth roots and the maxillary sinus. After taking micro CTs of 5 human maxillary bones, horizontally sectioned images of...
متن کاملBiologic Width around Dental Implants: An Updated Review
Soft tissue-implant interface is an important anatomical feature contributing to the long-term success of dental implants. Based on the available evidence, different factors may influence biological width around implants including the surgical technique, implant loading, implant surface properties, abutment materials, implant position, and width of the peri-implant mucosa. The purpose of the pr...
متن کاملDiagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites
PURPOSE The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose 180° acquisition protocol versus a conventional 360° acquisition protocol. MATERIALS AND METHODS Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 grou...
متن کاملHistologic evaluation of root-surface healing after root contact or approximation during placement of mini-implants.
INTRODUCTION Placement of mini-implants carries with it the risk of iatrogenic damage to the adjacent root surfaces. The aims of this study were to assess the type of trauma incurred on tooth roots after contact or approximation with mini-implants during placement, and to observe and analyze the healing responses via histologic analysis. METHODS Four male minipigs were used as experimental su...
متن کامل