Motion Measurements in Low-Contrast X-ray Imagery
نویسندگان
چکیده
Measuring motion in medical imagery becomes more and more important, in particular for object tracking, image registration, and local displacement measurements. Often, the requirements on the measurement precision are high compared to the image quality. Especially in megavoltage X-ray images (portal images), which are used to check the position of patients in high precision radiotherapy, render low contrast, blur, and noise accurate measurements difficult. In this work we review the framework of a generic matching algorithm only based on the image signal and not on binary image features. Thus, the often unreliable step of feature extraction in such imagery is circumvented. Another major advantage is the possibility of self-diagnosis, which is used for restricting the transformation in motion measurements if the image quality is not sufficient. The matching leads to an estimate of parts of the rigid 3D motion of the patient during radiotherapy, based on the measurements in the projected 2D portal images. The method of digitally reconstructed radiographs (DRR) allow for the computation of error free reference images, avoiding the additional step of therapy simulation. The multi-modal match between such DRRs and portal images lead to an estimate of the patient position during radiotherapy treatment. Results of generated data with known ground truth as well as results of a multimodal match are presented.
منابع مشابه
Motion Measurements in Low-contrast X-ray Imagery 1
1 This report has been accepted in shorter form to MICCAI '98. Abstract Measuring motion in medical imagery becomes more and more important, in particular for object tracking, image registration, and local displacement measurements. Often, the requirements on the measurement precision are high compared to the image quality. Especially in megavoltage X-ray images (portal images), which are used ...
متن کاملخواص مغناطیسی و ساختاری ابررسانای 2223- Bi آلاییده با کادمیوم
In this paper, Bi1.64-xPb0.36CdxSr2Ca2Cu3Oy (BPCSCCO) superconductor with x = 0.0, 0.02, 0.04 and 0.06 is made by the solid state reaction method. The magnetic susceptibility measurements were performed using AC susceptometer. The microstructure and morphology of the samples have been studied by X-ray diffraction, scanning electron microscope and energy dispersive X-ray. The results show that t...
متن کاملEnhancement of X-Ray Emission from Laser Irradiated Metals for High-Contrast X-ray Microscopy: The Effect of Initial Target Density
This article has no abstract.
متن کاملA study of densitometry comparison among three radiographic processing solutions
ABSTRACT Background: The radiographic image accuracy depends on the X-ray film information visibility. Good visibility is found by good contrast. Radiation exposure parameters (kVp, mAs) and film processing conditions have impact on contrast. In dentistry radiography machines, exposure time and processing procedure are set by radiographer. No optimized exposure time and process...
متن کاملPhotoemission measurements of Ultrathin SiO2 film at low take-off angles
The surface and interfacial analysis of silicon oxide film on silicon substrate is particularly crucial in the nano-electronic devices. For this purpose, series of experiments have been demonstrated to grow oxide film on Si (111) substrate. Then these films have been used to study the structure of the film by using X-ray photo emission spectroscopy (XPS) technique. The obtained results indicate...
متن کامل