Intraocular pressure measurement by radio wave telemetry.

نویسندگان

  • Amit Todani
  • Irmgard Behlau
  • Mark A Fava
  • Fabiano Cade
  • Daniel G Cherfan
  • Fouad R Zakka
  • Frederick A Jakobiec
  • Yuqing Gao
  • Claes H Dohlman
  • Samir A Melki
چکیده

PURPOSE To determine the biocompatibility of a new wireless intraocular pressure (IOP) transducer (WIT) in rabbit eyes and to correlate its measurements with other pressure-measuring devices. METHODS The WIT is a ring-shaped intraocular device that allows wireless IOP measurements through radiofrequency. It was implanted into six eyes of New Zealand White rabbits after extracapsular lens extraction. A sham rabbit eye with no transducer implanted was used as a control. The animals were observed and examined by microscopy at various intervals up to 25 months after surgery. IOP was measured at various intervals by pneumotonometry, tonometry, WIT, and manometry. The data from the various devices were compared and analyzed for reproducibility. Two eyes were enucleated at 5.5 and 20 months after implantation and analyzed by histology. RESULTS The WIT appears to be well tolerated in the rabbit eye, with no evidence of significant inflammation or scar formation by microscopic in vivo examination. Histology did not reveal intraocular inflammation or membrane formation. Repeated IOP measurements with pneumotonometry, tonometry, and the WIT resulted in SDs of 2.70 mm Hg, 3.35 mm Hg, and 0.81 mm Hg, respectively. The concordance between the WIT and direct manometry measurements was high. A downward drift in IOP measured by the WIT was noted in three rabbits, necessitating recalibration. CONCLUSIONS The WIT is well tolerated by the rabbit eye. Its measurements are reproducible and in close concordance with manometry. A downward IOP drift warrants further investigation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliable intraocular pressure measurement using automated radio-wave telemetry

PURPOSE To present an autonomous intraocular pressure (IOP) measurement technique using a wireless implantable transducer (WIT) and a motion sensor. METHODS The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS) comprising of a WIT and an external antenna aided by a motion se...

متن کامل

Measurement of intraocular pressure by telemetry in conscious, unrestrained rabbits.

PURPOSE The aim of this study was to develop a system for the continuous recording of the intraocular pressure (IOP) in rabbits maintained in their normal environment. A telemetric system originally designed for the measurement of cardiovascular parameters in unrestrained, conscious laboratory animals was adapted for this purpose. METHODS Experiments were performed in adult albino female rabb...

متن کامل

Determination of Central Venous Pressure from Intraocular Pressure

Background: In many clinical situations, knowledge of central venous pressure (CVP) is important.  Measurement of CVP is not always possible. Objective: To determine if intraocular pressure (IOP) can be used as an estimate for CVP. Methods: IOP and CVP were measured concurrently in 30 candidates of coronary artery bypass graft surgery.  Those with carotid artery or jugular venous diseases as we...

متن کامل

Miniaturized Blood Pressure Telemetry System with RFID Interface

This work deals with the development and characterization of a potentially implantable blood pressure telemetry system, based on an active Radio-Frequency IDentification (RFID) tag, International Organization for Standardization (ISO) 15693 compliant. This approach aims to continuously measure the average, systolic and diastolic blood pressure of the small/medium animals. The measured pressure ...

متن کامل

Tail‐Cuff Technique and Its Influence on Central Blood Pressure in the Mouse

BACKGROUND Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 13  شماره 

صفحات  -

تاریخ انتشار 2011