Peak-to-Background Method for Standardless Electron Microprobe Analysis of Particles

نویسنده

  • R. Van Grieken
چکیده

A peak-to-background method was implemented for standardless electron microprobe analysis of bulk samples and particles. First, a study on the choice of the beam entry point was performed; the region of the particle closest to the detector proved to be the most convenient. Then, a very simple algorithm, which does not require any kind of standard, was developed for particle analysis. This method was tested for glass standard particles and the results were compared with those given by other methods; the proposed standardless approach appeared to yield very satisfactory results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of atmospheric particles by electron probe X-ray microanalysis.

Microchemical glass standards were used to validate a quantitation method based on peak-to-background (P/B) ratios from electron probe x-ray microanalysis spectra. This standardless method was applied to the determination of concentrations of individual particles from Malpha or Lalpha lines, as well as from Kalpha lines. The algorithm was tested on particulate glass samples for diameters rangin...

متن کامل

Application of Monte Carlo Calculations to Improve Quantitative Electron Probe Microanalysis

The generation of x rays from solid samples under electron bombardment is the basis of electron probe microanalysis (EPMA), a widely used technique for materials analysis. The problem of quantitative analysis, i.e. the transformation of the measured x-ray intensities into element concentrations, is generally solved by means of approximate, semi-empirical algorithms. These algorithms provide rel...

متن کامل

Quantification Of Actinides By EPMA: a New Accurate Standardless Approach

Electron probe microanalysis (EPMA) is used to quantify with a high accuracy the amount of different elements present on a sample of unknown composition. In the nuclear field, EPMA is largely used to quantify the amount of actinides present in fresh and irradiated fuels. EPMA is also used to manage waste disposal, to analyze sample from severe accidents and to assess the design of next-generati...

متن کامل

Electron Microprobe Analysis in Guided Tissue Regeneration: A Case Report

OBJECTIVES Several procedures have been advocated as regenerative procedures in periodontology, but one of the most widely used techniques up to now is guided tissue regeneration (GTR). Likewise, different assessment methods based on clinical, radiographic or histological measurements have been proposed for the evaluation of these regenerative procedures. However, none of the methods used for h...

متن کامل

The Atomic Number Dependence of the X-Ray Continuum Intensity and the Practical Calculation of Background in Energy Dispersive Electron Microprobe Analysis

Computer fitting techniques have been used to derive a new expression for the relationship between X-ray continuum intensity and atomic number for a range of electron accelerating potentials up to 25 kV, continuum energies up to 10 keV and average atomic numbers up to thirty. A practical approach to background corrections in energy dispersive electron microprobe analysis, which utilizes this ex...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005