Bone-implant contact and bone quality: evaluation of expected and actual bone contact on machined and osseotite implant surfaces.

نویسندگان

  • Paolo Trisi
  • Richard Lazzara
  • Walter Rao
  • Alberto Rebaudi
چکیده

This article introduces a new technique using histomorphometrics to estimate the extent of bone-to-implant contact that might be expected on an implant surface in relation to the quality of the surrounding bone. Two implant surfaces, one machined and one Osseotite, were compared on the same implant in the same patient Eleven of these custom-made 2-mm-diameter implants were placed in the posterior maxilla and allowed to integrate. After 6 months of nonloaded healing, implants were trephined with surrounding bone tissue and prepared into histologic sections. Digitized images were analyzed at 50x magnification with image-analysis software. Bone surface area was calculated over the entire microscopic field, and the actual bone-to-implant contact for each implant surface was measured. The expected bone-to-implant contact was calculated by superimposing the profile of the implant threads on the bone image a small increment (0.15, 0.5, or 1.0 mm) from the actual implant site and counting the linear amount of bone that would be in contact with the implant surface. The actual bone-to-implant contact for Osseotite was greater than its expected bone-to-implant contact, whereas the actual bone-to-implant contact for the machined surface was mostly lower than the expected values. Thus, the Osseotite surface appears to exert a positive effect on the amount of bone approaching the implant surface and can be described as conductive, while the machined surface is nonconductive. This technique may serve to predict the clinical success that the Osseotite surface will demonstrate in poor-quality bone.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A human histologic analysis of osseotite and machined surfaces using implants with 2 opposing surfaces.

A human histologic study was conducted to compare the percentage of bone-to-implant contact (BIC) at 6 months for Osseotite and machined, commercially pure titanium implant surfaces. To eliminate potential influences caused by differences in bone density at different intraoral locations, 2 mm x 5 mm, threaded, 2-surfaced titanium implants were manufactured; 1 side received the Osseotite surface...

متن کامل

تحلیل پایداری ایمپلنت دندانی و بررسی تاثیر عوامل موثر بر اتصال ایمپلنت- استخوان به کمک مدل اصطکاکی تماس

Background and Aims: Relative displacement of the implant with respect to bone and quality of bone-implant contact play critical roles in the dental implant stability. The goal of this study was to investigate the dental implant stability using non-linear finite elements method. Therefore, bone-implant relative displacement due to applied force to the implant was calculated, and then an appropr...

متن کامل

Histologic comparison of a thermal dual-etched implant surface to machined, TPS, and HA surfaces: bone contact in vivo in rabbits.

PURPOSE To evaluate the bone contact percentage around a proprietary high-temperature dual-etched (DE) implant surface (Osseotite) versus implants with machined, hydroxyapatite (HA), and titanium plasma-sprayed (TPS) surfaces. MATERIALS AND METHODS Each implant type was placed in rabbit tibiae of the same animal and assessed at 1 to 8 weeks. Histologic sections were prepared and analyzed hist...

متن کامل

Removal torque and histomorphometric investigation of 4 different titanium surfaces: an experimental study in the rabbit tibia.

This study presents a histomorphometric and biomechanical comparison of bone response to commercially pure titanium screws with 4 different types of surface topographies placed in the tibial metaphysis of 12 rabbits. Each rabbit had 4 implants placed, 2 in each tibia. The 4 surface topographies were a machined surface, a grit-blasted surface, a plasma-sprayed surface, and an acid-etched (Osseot...

متن کامل

Machined and sandblasted human dental implants retrieved after 5 years: a histologic and histomorphometric analysis of three cases.

OBJECTIVE Human retrieved implants with an intact bone-implant interface play a pivotal role in validating data obtained from in vitro studies and animal experiments. This study presents a histologic and histomorphometric analysis of peri-implant tissue reactions and of the bone-titanium interface in three machined and sandblasted dental implants retrieved after a 5-year loading period. METHO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The International journal of periodontics & restorative dentistry

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 2002