Uncertainties in the Whole Range of the Calibration of a Thermocouple

نویسندگان

  • Peter Benkó
  • Rudolf Palenčár
چکیده

− This contribution describes the procedure of evaluating the calibration of thermocouple by means of its comparison with the thermocouple standard. In the process of thermocouple calibration by means of comparison, the resulting uncertainty specified by applying the generalized procedure for evaluating the calibration of measuring devices with continuous scale. The advantage of this method of evaluation is the determination of uncertainties in the whole range of the calibration. The conclusion of this paper states the illustrated differencies between cases when covariances are into account or are not.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

Infrared Thermopile Temperature Measurement Technique in Microwave Heating Systems

Temperature measurement in microwave systems is essential for thermally driven processes, namely, catalytic reactions and ceramic sintering. Although, the application of direct thermometry methods, namely, thermocouples, have been commonly articulated in the available literature, however, contacted temperature measurement mechanisms have aroused concerns associated with the disruption of the el...

متن کامل

National Institute of Standards and Technology Standard Reference Materials Standard Reference Material 1749 : Au / Pt Thermocouple Thermometer

Standard Reference Material (SRM) 1749 is a lot of 18 specially-constructed gold versus platinum (Au/Pt) thermocouple thermometers, each calibrated on the International Temperature Scale of 1990 (ITS-90) and supplied with integral lead wires and a protective sheath. It is the most accurate thermocouple available over the range 0 °C to 1000 °C, with an expanded uncertainty (k=2) less than 8.3 m°...

متن کامل

Uncertainty Analysis in MRI-based Polymer Gel Dosimetry

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

متن کامل

Calibration and evaluation of water infiltration models in different soil textures

Accurate estimation of water infiltration into the soil is important for the design of irrigation systems. Therefore, calibration of different models is necessary to estimate the permeability in different regions. The aim of the present study was to calibrate and evaluate the models of Kastiakov, Kastiakov modified, Philip, SCS, Novell, and Horton in different soil textures. To evaluate the acc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009