A comparison between transcutaneous and total serum bilirubin in healthy-term greek neonates with clinical jaundice.

نویسندگان

  • Charalambos Neocleous
  • Alkistis Adramerina
  • Stefanos Limnaios
  • Symeon Symeonidis
  • Chrysoula Spanou
  • Marina Malakozi
  • Evangelos Mpampalis
چکیده

The accuracy of transcutaneous bilirubin meters has been assessed in newborns from various ethnic backgrounds. However, there are limited data on Greek newborns. Our study examined the accuracy of transcutaneous bilirubin measurements in clinically jaundiced healthy-term Greek newborns, using total serum bilirubin as the reference standard, in order to re-evaluate our local guidelines about neonatal jaundice. Clinically jaundiced newborns requiring total serum bilirubin level estimation were recruited prospectively. 368 pairs of total serum bilirubin/transcutaneous bilirubin measurements were taken in 222 newborns, using a direct spectrophotometric device and the BiliCheck device, respectively. The level of agreement between the obtained transcutaneous bilirubin and total serum bilirubin values was assessed. Our data were analysed using the Stata/SE 12.0 (StataCorp LP, USA) statistical programme. The mean (± SD) TSB was 225.4 ± 25.4 μmol/l and the mean (± SD) TcB was 237.9 ± 21.0 μmol/l. The correlation between the values was poor (Pearson's correlation coefficient 0.439; Lin's concordance coefficient 0.377 [95% CI 0.301 to 0.453]; P<0.001). The Bland-Altman analysis demonstrated that transcutaneous bilirubin measurements tended to overestimate the total serum bilirubin value (mean difference 12.5 ± 24.9 μmol/l), with wide 95% limits of agreement (-36.2 μmol/l to 61.3 μmol/l). Transcutaneous bilirubin values did not correlate well with total serum bilirubin values, being often imprecise in predicting the actual total serum bilirubin levels. This permits us to continue estimating total serum bilirubin in clinically jaundiced newborns according to our local guidelines, in order to safely decide the appropriate care plan.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison between Transcutaneous Bilirubin (TcB) and Total Serum Bilirubin (TSB) Measurements in Term Neonates

Background: Transcutaneous bilirubinometry (TCB) is a simple method for estimating bilirubin levels in neonates. This method is noninvasive, quick, and painless. We aimed to compare serum and cutaneous bilirubin measurements in term neonates.Method: In this descriptive cross-sectional study, 200 neonates with icter with birth weights of at least 2500 grams were studied. TCB was measured using a...

متن کامل

Evaluation of the first day transcutaneous bilirubin (TcB) level as a predictor of hyperbilirubinemia in healthy term neonates

Background: The readmission rate for neonatal jaundice has been increased in recent years. This has been attributed to shorter length of postpartum hospital stays without comprehensive follow-up. The purpose of this study was to determine the diagnostic value of pre-discharge transcutaneous bilirubin (TcB) levels for prediction of subsequent hyperbilirubinemia in healthy term neonates. Metho...

متن کامل

Effect of Massage Therapy on Transcutaneous Bilirubin Level in Healthy Term Neonates: Randomized Controlled Clinical Trial

Background: Neonatal jaundice is a common condition in approximately 60% of term newborns during the first week after birth. Therefore, it is necessary to detect methods for the prevention of this problem.This study was conducted to evaluate the impact of massage therapy on transcutaneous bilirubin level in healthy term newborns. Methods: The present study was conducted on102 healthy term newbo...

متن کامل

Evaluation of the Predictive Value of Umbilical Cord Serum Bilirubin Level for the Development of Subsequent Hyperbilirubinemia in Term and Late-Preterm Neonates

Background: Considering the increasing rates of early hospital discharge and kernicterus in healthy full term newborns, timely identification of neonates at risk of severe hyperbilirubinemia is of great significance. The aim of this study was to investigate the predictive value of umbilical cord serum (UCS) bilirubin level for subsequent hyperbilirubinemia. Moreover, we compared the predictive ...

متن کامل

Comparing transcutaneous bilirubin versus serum bilirubin measurement using spectrophotometry for jaundice screening of full-term neonates

Background: Neonatal jaundice is an almost common problem among neonates that may cause complications such as kernicterus in severe cases. Since early diagnosis and proper treatment of neonatal jaundice is vital to prevent the related complications, it is necessary to check bilirubin before discharging the neonates. There are several evaluating and diagnostic methods to measure the level of bil...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Prague medical report

دوره 115 1-2  شماره 

صفحات  -

تاریخ انتشار 2014