Release of Intracoronary Microparticles during Stent Implantation into Stable Atherosclerotic Lesions under Protection with an Aspiration Device
نویسندگان
چکیده
OBJECTIVE Stent implantation into atherosclerotic coronary vessels impacts on downstream microvascular function and induces the release of particulate debris and soluble substances, which differs qualitatively and quantitatively between native right coronary arteries (RCAs) and saphenous vein grafts on right coronary arteries (SVG-RCAs). We have now quantified the release of microparticles (MPs) during stent implantation into stable atherosclerotic lesions and compared the release between RCAs and SVG-RCAs. METHODS In symptomatic, male patients with stable angina and a stenosis in their RCA or SVG-RCA, respectively (n = 14/14), plaque volume and composition were analyzed using intravascular ultrasound before stent implantation. Coronary aspirate was retrieved during stent implantation with a distal occlusion/aspiration device and divided into particulate debris and plasma. Particulate debris was weighed. Platelet-derived MPs (PMPs) were distinguished by flow cytometry as CD41+, endothelium-derived MPs (EMPs) as CD144+, CD62E+ and CD31+/CD41-, leukocyte-derived MPs as CD45+, and erythrocyte-derived MPs as CD235+. RESULTS In patients with comparable plaque volume and composition in RCAs and SVG-RCAs, intracoronary PMPs and EMPs were increased after stent implantation into their RCAs and SVG-RCAs (CD41+: 2729.6 ± 645.6 vs. 4208.7 ± 679.4 and 2355.9 ± 503.9 vs. 3285.8 ± 733.2 nr/µL; CD144+: 451.5 ± 87.9 vs. 861.7 ± 147.0 and 444.6 ± 74.8 vs. 726.5 ± 136.4 nr/µL; CD62E+: 1404.1 ± 247.7 vs. 1844.3 ± 378.6 and 1084.6 ± 211.0 vs. 1783.8 ± 384.3 nr/µL, P < 0.05), but not different between RCAs and SVG-RCAs. CONCLUSION Stenting in stable atherosclerotic lesions is associated with a substantial release not only of PMPs, but also of EMPs in RCAs and SVG-RCAs. Their release does not differ between RCAs and SVG-RCAs. TRIAL REGISTRATION ClinicalTrials.gov NCT01430884.
منابع مشابه
The need for stent-lesion matching to optimize outcomes of intracoronary stent implantation.
Intracoronary stents have markedly improved the outcomes of catheter-based coronary interventions. Intracoronary stent implantation rates of over 90% during coronary angioplasty are common. Stent implantations are associated with a small but statistically significant number of adverse outcomes including restenosis, thrombosis, strut malapposition, incomplete strut endothelialization, and variou...
متن کاملTRANSLATIONAL PHYSIOLOGY Aspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris
Kleinbongard P, Baars T, Möhlenkamp S, Kahlert P, Erbel R, Heusch G. Aspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris. Am J Physiol Heart Circ Physiol 305: H1222–H1229, 2013. First published August 9, 2013; doi:10.1152/ajpheart.00358.2013.—Stent implantation into atherosclerotic coronary arteries releases particulate deb...
متن کاملOverview of Intracoronary Brachytherapy for in-Stent Restenosis of a Drug-Eluting Stent
Percutaneous coronary intervention with stenting is considered recently as the most common procedure for the treatment of symptomatic coronary. The article reviewed 41 studies published during 1997-2019 on intracoronary brachytherapy for in-stent restenosis of a drug-eluting stent. Intracoronary radiation therapy was finally confirmed in the setting of in-stent restenosis using as adjunctive th...
متن کاملOptical Coherence Tomography Imaging: Novel Insights into the Vascular Response After Coronary Stent Implantation
Optical coherence tomography (OCT) is a high-resolution imaging technique that is increasingly used for intracoronary imaging to characterize coronary atherosclerotic plaques and vascular responses after coronary stent implantation. Introduction of optical frequency-domain imaging (OFDI; second generation OCT) has simplified practical use of this novel imaging modality resulting in a more wides...
متن کاملAspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris.
Stent implantation into atherosclerotic coronary arteries releases particulate debris and soluble substances that contribute to impaired microvascular perfusion. Here we addressed the potential for microvascular obstruction in patients with stenotic native right coronary arteries (nRCA) compared with saphenous vein grafts on right coronary arteries (SVG-RCA). We enrolled symptomatic, male patie...
متن کامل