Influence of differences between cable system and overhead lines
نویسنده
چکیده
One way to increase distribution network reliability is to replace traditional overhead lines with underground cables. To fully utilize these investments, network owners will have to adjust their reliability engineering methods to suit the new cable networks. In this paper different condition assessment methods as well as improved failure statistics for cable systems are considered. The paper is based on information from project reports and scientific papers. In addition a number of Swedish distribution network owners have been asked to share their opinion of reliability engineering work of today and the future. The methods used for distribution system condition assessment change as overhead lines are replaced by underground cable. Visual inspections can no longer be used and diagnostic methods are instead introduced. The diagnostic methods are costly to perform. To become frequently used they must prove to be efficient enough to justify the financial means required. New, improved, diagnostic methods are under development and since most cable failures are related to component properties the use of diagnostic methods is likely to increase. Statistics show that a majority of the cable system failures are ageing failures. The ageing failures do not to any large extent depend on environmental factors but on component properties. This implies that component lifetime standard deviation decreases as component data are related to the statistics, yet failure statistics is at present not related to component data. A majority of the network owners contributing to this paper agree that the nature of cable failures, except excavation failures, makes it interesting and useful to related cable data to failure statistics and to share the statistics with other network owners. Several Swedish distribution network owners are in the process of installing new program for network analysis. One challenge is to decide which component data that shall be related to the failure statistics. Operational age, maintenance history, manufacturer and year of manufacturer are four manageable factors which influence on failure statistics is already established but yet not thoroughly evaluated. In addition the method of cable excavation is suggested as a fifth interesting factor related to cable system reliability.
منابع مشابه
Power Cable Protection in Transmission System
Power cable is widely used in Extra High Voltage (EHV), High Voltage (HV) transmission, Medium Voltage (MV) sub-transmission, and MV / Low Voltage (LV) distribution applications. Basically, the protection principles used for cable are similar with the ones for overhead transmission line. However, the inherent characteristics of cables make its fault behavior more complicate than that of transmi...
متن کاملA Novel Method to Reconstruct Overhead High-Voltage Power Lines Using Cable Inspection Robot LiDAR Data
Overhead high-voltage power lines are key components of power transmission and their monitoring has a very significant influence on security and reliability of power system. Advanced laser scanning techniques have been widely used to capture three-dimensional (3D) point clouds of power system scenes. Nevertheless, power line corridors are found in increasingly complex environments (e.g., mounta...
متن کاملتخمین عمر عایقی کابل های فشار قوی XLPE تحت تنش های حرارتی، الکتریکی و همزمان
The aging of insulating materials can be estimated by an electrical breakdown occurring in electrical components so that the relationship between lifetime, failure probability and reliability of electrical components may be studied using the life models in high voltage cables networks. In last decades with attention to higher features as electrical, thermal, mechanical characteristic, widely cr...
متن کاملمکان یابی خطا در شبکه های توزیع فشار متوسط دو مداره به روش امپدانسی
Power distribution feeders contains many laterals, sub-laterals, different number of circuit line, load taps, balanced and unbalanced load, different type of lines (cable or overhead), different cross-sections and numerous distribution transformers with different capacities. Moreover, the voltage and current are measured only at the beginning of the feeder. Thus, fault location is very complex....
متن کاملResponse of Iranian Rice Recombinant Inbred Lines (Oryza sativa L.) to Salt Stress in Seedling Stage
Study of the morphological genetic diversity of 114 lines, which have been derived from the crosses between Tarom Mahalli and Khazar cultivars, has been performed at seedling stage as completely randomized design at the normal condition and salinity stress of 8 dS.m-1 in a hydroponic system. Significant differences were detected between genotypes for all traits. Mean of comparison demonstrated ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2007