Standard gas addition: a calibration method for handling temporal drifts of mass spectrometry-based sensors.
نویسندگان
چکیده
This work describes a new method for the correction of signal drift of a MS-based sensor by standard gas addition (SGA). It consists of introducing a gaseous He-Xe mixture continuously and independently of the carrier gas into the mass spectrometer source. To mimic the disturbances generated by periodical tuning of the mass detector, three series of adjustments were made to the main acquisition parameters. The influence of the SGA signal correction on the discriminating power of the data was evaluated from the analysis of three batches of cheeses by dynamic headspace coupled to mass spectrometry. SGA afforded a good correction of the main types of drift classically observed in mass spectrometry.
منابع مشابه
Multi-Residue Analysis of Pesticides in Pistachio Using Gas Chromatography-Mass Spectrometry (GC/MS)
Background: Analysis of pesticide residues in food and other environmental commodities have become an essential requirement for consumers, producers, food inspectors and authorities. This study is focused on validation of an accurate, rapid and reliable method for multi-residual analysis of pesticides in pistachio as a strategic crop for export and one of the main nuts in Iranian food basket.Me...
متن کاملSpiked Calibration Curve: A Valid Method for Simultaneous Analysis of Pesticides in Melon Using Gas Chromatography Mass Spectrometry (GC/MS)
Recently, with increasing public awareness of food safety, developments of some valid and rapidly analytical methods are required for the determination of residual pesticides in crops.This study was conducted on validation of a reliable, accurate and precise method for multi analysis of pesticides residue in melon as a main fruit in Iranian food basket. A reliable, and valid method...
متن کاملImprovements in the methodology of monitoring sulfur mustard exposure by gas chromatography-mass spectrometry analysis of cleaved and derivatized blood protein adducts.
An analytical method for determining exposure to 2,2'-dichlorodiethyl sulfide (sulfur mustard, HD) has been enhanced. The method is based on the cleavage of adducted HD (protein-hydroxyethylthioethyl esters) to produce thiodiglycol. Following cleavage, a deuterated internal standard is added, and the analytes are extracted, derivatized, and analyzed by gas chromatography-negative ion chemical i...
متن کاملDevelopment of a GC-MS Method for Determination of various Polycyclic Aromatic Hydrocarbons in Iranian Traditional and Semi-industrial Taftoon Bread
This research reports a validated multi-residue method based on gas chromatography coupled mass spectrometry technique for analysis of 24 Polycyclic Aromatic Hydrocarbons (PAHs) in traditional and semi-industrial Taftoon bread using QuEChERS sample preparation. Matrix effect studies were performed by comparing the slopes of solvent based standard calibration curves and spiked calibration curves...
متن کاملDevelopment of a GC-MS Method for Determination of various Polycyclic Aromatic Hydrocarbons in Iranian Traditional and Semi-industrial Taftoon Bread
This research reports a validated multi-residue method based on gas chromatography coupled mass spectrometry technique for analysis of 24 Polycyclic Aromatic Hydrocarbons (PAHs) in traditional and semi-industrial Taftoon bread using QuEChERS sample preparation. Matrix effect studies were performed by comparing the slopes of solvent based standard calibration curves and spiked calibration curves...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Analytical chemistry
دوره 74 10 شماره
صفحات -
تاریخ انتشار 2002