On a ghost artefact in ultra low field magnetic resonance relaxation imaging.

نویسندگان

  • P Volegov
  • L Schultz
  • M Espy
چکیده

Nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) are widely used techniques across numerous disciplines. While typically implemented at fields >1T, there has been continuous interest in the methods at much lower fields for reasons of cost, material contrast, or application. There have been numerous demonstrations of MR at much lower fields (from 1μT to 1mT), the so-called ultra-low field (ULF) regime. Approaches to ULF MR have included superconducting quantum interference device (SQUID) sensor technology for ultra-sensitive detection and the use of pulsed pre-polarizing fields to enhance the signal strength. There are many advantages to working in the ULF regime. However, due to the low strength of the measurement field, acquisition of MRI at ULF is more susceptible to ambient fields that cause image distortions. Imaging artifacts can be caused by transients associated with non-ideal field switching and from remnant fields in magnetic shielding, among other causes. In this paper, we introduce a general theoretical framework that describes effects of non-ideal measurement field inversion/rotation due to presence of these transient fields. We illustrate imaging artifacts via simulated and experimental examples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST

Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...

متن کامل

Ultra-low-field NMR relaxation and diffusion measurements using an optical magnetometer.

Nuclear magnetic resonance (NMR) relaxometry and diffusometry are important tools for the characterization of heterogeneous materials and porous media, with applications including medical imaging, food characterization and oil-well logging. These methods can be extremely effective in applications where high-resolution NMR is either unnecessary, impractical, or both, as is the case in the emergi...

متن کامل

A New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite

Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This study aims to evaluate iron oxide–4A nanocomposite ability to act as a magnetic resonance imaging contrast agent.Materials and Methods: Iron oxide–4A nanocomposite (F4A) was syn...

متن کامل

Minimization of Nyquist ghosting for echo-planar imaging at ultra-high fields based on a "negative readout gradient" strategy.

PURPOSE To improve the traditional Nyquist ghost correction approach in echo planar imaging (EPI) at high fields, via schemes based on the reversal of the EPI readout gradient polarity for every other volume throughout a functional magnetic resonance imaging (fMRI) acquisition train. MATERIALS AND METHODS An EPI sequence in which the readout gradient was inverted every other volume was implem...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance

دوره 243  شماره 

صفحات  -

تاریخ انتشار 2014