Quality of MR thermometry during palliative MR-guided high-intensity focused ultrasound (MR-HIFU) treatment of bone metastases
نویسندگان
چکیده
BACKGROUND Magnetic resonance (MR)-guided high-intensity focused ultrasound has emerged as a clinical option for palliative treatment of painful bone metastases, with MR thermometry (MRT) used for treatment monitoring. In this study, the general image quality of the MRT was assessed in terms of signal-to-noise ratio (SNR) and apparent temperature variation. Also, MRT artifacts were scored for their occurrence and hampering of the treatment monitoring. METHODS Analyses were performed on 224 MRT datasets retrieved from 13 treatments. The SNR was measured per voxel over time in magnitude images, in the target lesion and surrounding muscle, and was averaged per treatment. The standard deviation over time of the measured temperature per voxel in MRT images, in the muscle outside the heated region, was defined as the apparent temperature variation and was averaged per treatment. The scored MRT artifacts originated from the following sources: respiratory and non-respiratory time-varying field inhomogeneities, arterial ghosting, and patient motion by muscle contraction and by gross body movement. Distinction was made between lesion type, location, and procedural sedation and analgesic (PSA). RESULTS The average SNR was highest in and around osteolytic lesions (21 in lesions, 27 in surrounding muscle, n = 4) and lowest in the upper body (9 in lesions, 16 in surrounding muscle, n = 4). The average apparent temperature variation was lowest in osteolytic lesions (1.2°C, n = 4) and the highest in the upper body (1.7°C, n = 4). Respiratory time-varying field inhomogeneity MRT artifacts occurred in 85% of the datasets and hampered treatment monitoring in 81%. Non-respiratory time-varying field inhomogeneities and arterial ghosting MRT artifacts were most frequent (94% and 95%) but occurred only locally. Patient motion artifacts were highly variable and occurred less in treatments of osteolytic lesions and using propofol and esketamine as PSA. CONCLUSIONS In this study, the general image quality of MRT was observed to be higher in osteolytic lesions and lower in the upper body. Respiratory time-varying field inhomogeneity was the most prominent MRT artifact. Patient motion occurrence varied between treatments and seemed to be related to lesion type and type of PSA. Clinicians should be aware of these observed characteristics when interpreting MRT images.
منابع مشابه
Feasibility of volumetric MRI-guided high intensity focused ultrasound (MR-HIFU) for painful bone metastases
BACKGROUND Magnetic resonance-guided high intensity focused ultrasound (MR-HIFU) has recently emerged as an effective treatment option for painful bone metastases. We describe here the first experience with volumetric MR-HIFU for palliative treatment of painful bone metastases and evaluate the technique on three levels: technical feasibility, safety, and initial effectiveness. METHODS In this...
متن کاملMR-guided high-intensity focused ultrasound for noninvasive cancer treatment
Magnetic resonance (MR)-high-intensity focused ultrasound (HIFU) is an innovative, noninvasive tumour ablation technique. MR imaging and focused ultrasound are combined allowing real-time anatomic guidance and temperature mapping during treatment. Recently, the volumetric ablation approach has been introduced in order to reduce treatment length and provide more homogeneous tumour ablation. Afte...
متن کاملSonalleve MR-HIFU with DISC Philips MR-guided High Intensity Focused Ultrasound with Direct Skin Cooling
High Intensity Focused Ultrasound guided by Magnetic Resonance Imaging (also known as MR-guided HIFU, MRgHIFU, or MRgFUS) is a therapy technique which uses focused ultrasound waves to heat and coagulate tissue deep inside the body without damaging intervening tissue and offers an novel, non-invasive treatment option for solid tumors. The Philips Sonalleve MR-HIFU system, initially released in 2...
متن کامل3D MR neurography targeted peripheral nerve ablation with MR-guided high intensity focused ultrasound (MR-HIFU): initial results of a feasibility study in a swine model
Background/introduction MR-guided HIFU is an effective treatment for metastatic bone pain through periosteal nerve ablation,[1] and is being investigated for treating back pain through facet joint denervation.[2] For peripheral neuropathy, ultrasound-guided HIFU has been investigated preclinically as a means of achieving either an irreversible conduction block to treat severe spasticity [3], or...
متن کاملEvaluation of Quality of Life Outcomes Following Palliative Treatment of Bone Metastases with Magnetic Resonance-guided High Intensity Focused Ultrasound: An International Multicentre Study
AIMS To determine quality of life (QoL) outcomes after palliation of pain from bone metastases using magnetic resonance-guided high intensity focused ultrasound (MR-guided HIFU), measured using the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C15-PAL and the QLQ-BM22 questionnaires. MATERIALS AND METHODS Twenty patients undergoing MR-guided HIFU in an international m...