Adenosine stress cardiovascular magnetic resonance with variable-density spiral pulse sequences accurately detects coronary artery disease: initial clinical evaluation.
نویسندگان
چکیده
BACKGROUND Adenosine stress cardiovascular magnetic resonance perfusion imaging can be limited by motion-induced dark-rim artifacts, which may be mistaken for true perfusion abnormalities. A high-resolution variable-density spiral pulse sequence with a novel density compensation strategy has been shown to reduce dark-rim artifacts in first-pass perfusion imaging. We aimed to assess the clinical performance of adenosine stress cardiovascular magnetic resonance using this new perfusion sequence to detect obstructive coronary artery disease. METHODS AND RESULTS Cardiovascular magnetic resonance perfusion imaging was performed during adenosine stress (140 μg/kg per minute) and at rest on a Siemens 1.5-T Avanto scanner in 41 subjects with chest pain scheduled for coronary angiography. Perfusion images were acquired during injection of 0.1 mmol/kg Gadolinium-diethylenetriaminepentacetate at 3 short-axis locations using a saturation recovery interleaved variable-density spiral pulse sequence. Significant stenosis was defined as >50% by quantitative coronary angiography. Two blinded reviewers evaluated the perfusion images for the presence of adenosine-induced perfusion abnormalities and assessed image quality using a 5-point scale (1 [poor] to 5 [excellent]). The prevalence of obstructive coronary artery disease by quantitative coronary angiography was 68%. The average sensitivity, specificity, and accuracy were 89%, 85%, and 88%, respectively, with a positive predictive value and negative predictive value of 93% and 79%, respectively. The average image quality score was 4.4±0.7, with only 1 study with more than mild dark-rim artifacts. There was good inter-reader reliability with a κ statistic of 0.67. CONCLUSIONS Spiral adenosine stress cardiovascular magnetic resonance results in high diagnostic accuracy for the detection of obstructive coronary artery disease with excellent image quality and minimal dark-rim artifacts.
منابع مشابه
Adenosine stress CMR with variable density spiral pulse sequences accurately detects CAD with minimal dark-rim artifacts
Background Adenosine stress CMR perfusion imaging has numerous advantages over competing modalities for assessing CAD demonstrating high diagnostic and prognostic utility. However, adenosine stress CMR perfusion imaging is limited by motion-induced dark-rim artifacts (DRA) which may be mistaken for true perfusion abnormalities. We have previously demonstrated that a high-resolution variable-den...
متن کاملAdenosine stress CMR with spiral pulse sequences accurately detect CAD
Background Adenosine stress perfusion imaging with CMR has been limited by motion-induced dark-rim artifacts, which may be mistaken for true perfusion abnormalities. We have previously demonstrated that spiral pulse sequences can produce high quality first-pass perfusion images.[1] We have further improved this spiral technique using high-resolution variable density spiral trajectories and a no...
متن کاملEpicardial adipose tissue measured by magnetic resonance imaging predicts abnormal adenosine stress cardiovascular magnetic resonance imaging and future adverse cardiovascular events
Background A growing body of evidence demonstrates a quantitative association between Epicardial Adipose Tissue (EAT), cardiometabolic risk factors and measures of coronary artery disease (CAD). It is still unclear, however, if EAT is predictive of abnormal functional stress tests and clinical outcomes. The aim of this study is to elucidate the relationship between the total volume of EAT, the ...
متن کاملAdenosine stress CMR T1-mapping detects early microvascular dysfunction in patients with type 2 diabetes mellitus without obstructive coronary artery disease
BACKGROUND Type 2 diabetes mellitus (T2DM) is associated with coronary microvascular dysfunction in the absence of obstructive coronary artery disease (CAD). Cardiovascular magnetic resonance (CMR) T1-mapping at rest and during adenosine stress can assess coronary vascular reactivity. We hypothesised that the non-contrast T1 response to vasodilator stress will be altered in patients with T2DM w...
متن کاملCorrection to: Adenosine stress CMR T1-mapping detects early microvascular dysfunction in patients with type 2 diabetes mellitus without obstructive coronary artery disease
In the original publication of this article [1] Fig. 1 was incorrect due to the use of a colour bar with wrong range in error.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation. Cardiovascular imaging
دوره 7 4 شماره
صفحات -
تاریخ انتشار 2014