Retrofit Control to Prevent ASD Nuisance Tripping Due to Power Quality Problems
نویسندگان
چکیده
Since the onset of automation, industry has relied on adjustable speed drives to accurately control the speed of motors. Recent advances have increased the number of adjustable speed drives hitting the market. The proper operation of the speed drives requires electrical supply with relatively high power quality which is not the case in most industrial facilities. Power quality problems such as harmonic, sag, swell, flicker, and unbalance can trip the speed drive with a wrong message, which is referred as a premature tripping. Although the power quality problems can be mitigated by using custom power devices, they are bulky and costly. Moreover, they themselves might adversely affect the operation of the adjustable speed drive. A comprehensive study done in this thesis presents the overlooked effect of the custom power devices on the speed drive stability. It is found that the speed drive system might trip due to its interaction with custom power devices. Obviously, it is vital to increase ASD immunity to premature tripping because of poor power quality or custom power. This thesis offers fast, efficient and robust algorithms to achieve this immunity by retrofitting the ASD control unit and integrating the power conditioning function with the adjustable speed drive. Therefore, the power quality problem is mitigated and the drive system performance is significantly enhanced. Such integration requires the modification of the control unit by considering various elements such as envelope tracking, phase-locked loop, symmetrical component extraction, and the controller. Simple but robust and fast algorithms are proposed for such elements based on a newly developed energy operator algorithm. The developed energy operator and the developed algorithms overcome the drawbacks of the existing algorithms.
منابع مشابه
Evaluating Power Quality at Medical Center
Background A large medical center in the southern United States experienced nuisance tripping of their equipment due to unexplained events on their electrical system. Realizing that nuisance tripping could be the result of any of a number of root causes, the facility contracted with S&C’s Power Systems Services Division to perform a complete power quality evaluation of their electrical system. ...
متن کاملImproved Performance of an Adjustable Speed Drives during Voltage Sag Condition
Voltage sags normally do not cause equipment damage but can easily disrupt the operation of sensitive loads such as electronic Adjustable Speed Drives (ASD’s). Voltage sags cause a momentary decrease in DC-link voltage triggering an under voltage trip leading to nuisance tripping of adjustable speed drives (ASD’s) employed in continuous-process industries which contributes to loss in revenue. A...
متن کاملProviding A New Characteristic for Overcurrent Relays
This with the integration of distributed generation (DG) to meshed distribution systems, the operating time of the protective system becomes a major concern in order to avoid nuisance DG tripping. This paper proposes a new tripping characteristic for directional overcurrent relays (DOCRs) that can achieve a higher possible reduction of overall relays operating time in meshed distribution networ...
متن کاملBlocking of Distance Relays Zone3 under Load Encroachment Conditions- A New Approach Using Phasor Measurements Technique
Cascaded tripping of power lines due to mal-operation of zone 3 distance relays was one of the main causes of many previous blackouts worldwide. Encroachment of load into the zone 3 characteristics is one of the main cause for the maloperation of the relays. By improving the operation of zone 3 of distance relays it is possible to prevent such mal-operations so that cascaded line tripping can b...
متن کاملProtective Relay Setting of the Tie Line Tripping and Load Shedding for the Industrial Power System
This paper presents the proper underfrequency relay settings to enhance the operation of industrial power systems with cogeneration facilities. A cogeneration unit was installed in the plant in 1996 to supply the power demand of the plant. The cogeneration unit always faces the shutdown problem when a severe fault occurs on the nearby Taipower network. It is, therefore, necessary to investigate...
متن کامل