[Non-invasive coronary angiography with 16 multidetector-row spiral computed tomography: a comparative study with invasive coronary angiography].

نویسندگان

  • Rubén Leta
  • Francesc Carreras
  • Xavier Alomar
  • Joan Monell
  • Joan García-Picart
  • Josep M Augé
  • Antonio Salvador
  • Guillem Pons-Lladó
چکیده

INTRODUCTION AND OBJECTIVES Non-invasive coronary artery angiography by 16 multidetector-row spiral computed tomography is a novel diagnostic tool whose reliability is still unclear. The aim of our study was to compare this technique with invasive coronary angiography. PATIENTS AND METHOD A total of 31 selected patients were examined with both angiographic methods. Non-invasive studies were performed with a helical computer tomography system (Toshiba Aquilion 16-slices). A contrast agent was injected into a peripheral vein, and cross-sectional images were reconstructed with a slice thickness of 0.5 mm or 1.0 mm. Findings from both techniques were analyzed according to a predetermined segmented anatomical model of the coronary artery. The detection and relevance of coronary artery lesions were evaluated, and lesions with a reduction in diameter of more than 50% were considered significant. RESULTS Non-invasive coronary angiography yielded an appropriate assessment in 88.4% of the coronary artery segments. The reasons that prevented correct segment evaluation were extensive coronary calcifications, inappropriate breath-hold, motion artefacts and small vessel size. Sensitivity and specificity for the detection of significant coronary lesions with the non-invasive method were 75% and 91%, respectively. Sensitivity and specificity for individual coronary artery segments were as follows: proximal, 89% and 93%; medial, 87% and 90%; distal, 50% and 90%; and secondary branches, 62% and 92%. CONCLUSIONS Non-invasive coronary artery angiography with 16 multidetector-row computed tomography is a powerful diagnostic tool, especially for the evaluation of the proximal and medial segments of the major coronary arteries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients.

AIMS A new generation of multidetector-row CT (MDCT) scanners allows complete coronary coverage using retrospective ECG gating and 1mm slices. The purpose of this study was to investigate the potential of high resolution MDCT angiography with retrospective gating for detection of coronary artery stenoses. METHODS AND RESULTS A total of 102 patients underwent both conventional and MDCT coronar...

متن کامل

Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the non-invasive evaluation of significant coronary artery disease.

AIMS Multidetector computed tomography coronary angiography (CTA) has emerged as a feasible imaging modality for non-invasive assessment of coronary artery disease (CAD). Recently, 320-row CTA systems were introduced, with 16 cm anatomical coverage, allowing image acquisition of the entire heart within a single heart beat. The aim of the present study was to assess the diagnostic accuracy of 32...

متن کامل

Non-invasive imaging of sutureless vein graft anastomosis with 16-slice multi-detector row spiral computed tomography.

Contrast-enhanced 16-slice multi-detector row spiral computed tomography (MDCT) has been shown to be useful for non-invasive visualization of aortocoronary bypass grafts (CABG). This new-generation scanner could be a good alternative to the common invasive coronary angiography. In this article, we report a patient operated on with the St. Jude Medical, Inc, Symmetry Bypass System (Aortic Connec...

متن کامل

Non-invasive detection and assessment of coronary artery disease with multidetector-row computed tomography.

The fast volume coverage of retrospective ECG-gated multidetector-row helical CT(MDCT)arrows for acquisition of the entire heart volume with nearly isotropic spatial resolution(0.5×0.5×0.6 mm)within a single breath-hold. The sub-millimeter spatial resolution enables depiction of the major and also of peripheral coronary artery segments with lumen diameter down to 1 mm. The results of studies of...

متن کامل

256- and 320-row coronary CTA: is more better?

This editorial refers to ‘The diagnostic accuracy of 256row computed tomographic angiography compared with invasive coronary angiography in patients with suspected coronary artery disease’, by S.-P. Chao et al., on page 1916 and ‘Diagnostic accuracy of 320-row multidetector computed tomography coronary angiography in the noninvasive evaluation of significant coronary artery disease’, by F.R. de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de cardiologia

دوره 57 3  شماره 

صفحات  -

تاریخ انتشار 2004